Skip to content

What are you looking for?


You may also like

ABB 35EK90 GJR5143100R0001 Bus Coupler UnitABB 35EK90 GJR5143100R0001 Bus Coupler UnitABB 35EK90 GJR5143100R0001 Bus Coupler Unit
ABB 35EK90 GJR5143100R0001 Bus Coupler Unit
ABB 35EK90 GJR5143100R0001 Bus Coupler Unit
ABB 35EK90 GJR5143100R0001 Bus Coupler Unit

ABB 35EK90 GJR5143100R0001 Bus Coupler Unit


Only 10 left - Selling fast

PRODUCT SKU : 35EK90 GJR5143100R0001

PRODUCT TYPE : Bus Coupler Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 35EK90 GJR5143100R0001, also cataloged as the 35EK90 Bus Coupler Unit, operates as a dedicated hardware component for inter-rack communications and bus interface conversion within ABB Procontic and Procontic T300 platforms. The module manages electrical isolation and data frame conversion between local rack backplane segments and external system buses. Operating within a physical footprint of 20.3 cm x 5.1 cm x 27.9 cm and weighing 0.2 kg, the unit executes high-speed signal routing without introducing processing delay.

Hardware Specifications

Parameter Specification
Model 35EK90 (GJR5143100R0001)
Base Model 35EK90
Brand ABB
Origin Switzerland
Weight 0.2 kg (0.44 lbs)
Dimensions 20.3 cm x 5.1 cm x 27.9 cm
Operating Temp 0 deg C to +55 deg C
Power Consumption Standard Backplane Draw
Compatible Platforms ABB Procontic, Procontic T300
Function Type Bus Coupler Unit

Backplane Bus Communication Velocity and Deterministic Networks

When integrated into ABB Procontic rack architectures, the coupler unit preserves high backplane bus communication velocity across expanded controller subracks. Low-latency signal conversion maintains deterministic network timing during cyclic I/O scanning and field bus message transmission. Firmware flash compatibility across connected controller cards ensures synchronized network addressing and system diagnostic execution across expanded bus racks.

Frequently Asked Questions

Q: What precautions are necessary regarding power state when installing or swapping the bus coupler unit?

A: Rack backplane power must be completely turned off prior to inserting or removing the unit. Hot-swapping the coupler can induce voltage transients across backplane contacts and disrupt communication across adjacent I/O racks.

Q: How is shielding managed across the bus coupler physical interface?

A: Interconnecting bus cables must utilize overall foil and braided shielding bonded to the cabinet ground plane to isolate communication lines from high-frequency electromagnetic noise.

Field Installation Guidelines

  • Isolate all rack power sources before aligning and inserting the card into its designated subrack slot.
  • Ensure backplane pin alignment is precise before pushing the module firmly into the chassis bus connector.
  • Secure top and bottom faceplate screws to ensure continuous ground contact between the metal faceplate and the subrack frame.
  • Maintain a minimum clearance of 100 mm above and below the card frame to facilitate natural convective heat dissipation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more