The ABB 2VAA008283R101, also cataloged as the BP03 Power Supply Base, operates as a dedicated hardware component for mechanical mounting and electrical backplane interface execution for power supply modules within ABB control platforms. The backplane base serves as the physical carrier designed to accommodate up to two SPS03-5V and two SPS03-15V power supply units simultaneously.

Hardware Specifications

Parameter Specification
Model BP03 (2VAA008283R101)
Brand ABB
Origin Sweden / Germany
Operating Temp -20 deg C to +70 deg C
Power Consumption Passive base structure (no direct power draw)
Module Accommodation 2x SPS03-5V and 2x SPS03-15V modules
Product Type Power Supply Base
Environmental Compliance WEEE Category 5 (Small Equipment)

Deterministic Network Backplane and System Signal Integrity

The BP03 base plate distributes high-current DC power rails directly to system subrack backplanes, maintaining deterministic performance across all interconnected controller and I/O slots. Internal power distribution busbars support stable voltage delivery without degrading backplane bus communication velocity during peak power demand cycles.

Designed as a modular physical interface, the hardware maintains full firmware flash compatibility across connected processing units by preventing electrical voltage ripple on DC supply channels. Grounding tracks integrated into the base assembly suppress common-mode electrical noise and maintain low impedance earth return paths.

Frequently Asked Questions

Q: Which power supply module configurations are directly supported by the BP03 base?

A: The BP03 base incorporates physical slots and electrical connectors configured to host two SPS03-5V and two SPS03-15V power supply units.

Q: Does the BP03 base require independent firmware configuration?

A: No, the BP03 is a passive backplane distribution assembly that operates without firmware or configuration software.

Q: What precautions are necessary before extracting or inserting power modules into the BP03 base?

A: Primary AC/DC input power sources to the system subrack should be isolated before seating or removing power modules to prevent contact arcing and voltage transients.

Field Installation Guidelines

  • De-energize all primary system power distribution feeds before installing or replacing the BP03 base unit.
  • Wear an anti-static wrist strap connected to cabinet earth ground to prevent electrostatic discharge during physical handling.
  • Align the BP03 base unit with cabinet mounting rails and fasten all retaining screws securely to maintain continuous chassis earth grounding.
  • Verify that multi-pin power connectors on the SPS03-5V and SPS03-15V modules align with guide pins on the BP03 base before seating.
  • Route high-current DC supply cabling through dedicated cabinet channels, separated from low-level communication and field signal wiring.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more