Skip to content

What are you looking for?


You may also like

ABB 1MRK002133-ACr01 Bay Control System CardABB 1MRK002133-ACr01 Bay Control System CardABB 1MRK002133-ACr01 Bay Control System Card
ABB 1MRK002133-ACr01 Bay Control System Card
ABB 1MRK002133-ACr01 Bay Control System Card
ABB 1MRK002133-ACr01 Bay Control System Card

ABB 1MRK002133-ACr01 Bay Control System Card


Only 10 left - Selling fast

PRODUCT SKU : 1MRK002133-ACr01

PRODUCT TYPE : Analog Digital Conversion Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 1MRK002133-ACr01, also cataloged as the 1MRK002133-AC Bay Control System Card, operates as a dedicated hardware component for multi-channel analog-to-digital signal conversion within ABB Bay Control System architectures.

Hardware Specifications

Parameter Specification
Model 1MRK002133-ACr01
Brand ABB
Origin Standard ABB Manufacturing
Weight 0.3 kg
Operating Temp -20 to +60 deg C
Power Consumption Backplane Auxiliary Powered
Input Channels 12 Analog Input Channels
ADC Resolution 16-bit
Sampling Rate 10 kSPS
Voltage Range 0-10 V
Current Range 4-20 mA
Galvanic Isolation 2500 V RMS
Protection Class IP20

Backplane Bus Communication Velocity & I/O Density Scaling

The bay control card digitizes 12 analog input signals across 0-10 V and 4-20 mA process loops with 16-bit resolution at a sample rate of 10 kSPS. 2500 V RMS galvanic isolation protects internal signal processing paths from ground potential rises and field line transients. High-speed backplane bus communication velocity guarantees rapid dispatch of sampled values to main control CPUs, while firmware flash compatibility ensures synchronized operational performance during I/O density scaling across system racks.

Frequently Asked Questions

Q: What input signal ranges and sampling speed are supported on the 1MRK002133-ACr01 card?

A: The card features 12 channels supporting 0-10 V and 4-20 mA inputs, converting data with 16-bit resolution at 10 kSPS per channel.

Q: What isolation level is provided between field wiring and internal backplane logic?

A: The board includes galvanic isolation rated at 2500 V RMS to protect backplane processing circuits from field electrical transients.

Field Installation Guidelines

  • Fully de-energize the host enclosure power supply prior to inserting or extracting the card from the chassis backplane slot.
  • Wear an ESD-grounded wrist strap during module handling to shield high-resolution 16-bit ADC circuitry from static discharge.
  • Route 4-20 mA current loops using twisted-shielded cable pairs and earth the cable shield braid at a single point on the main PE terminal.
  • Ensure all terminal connector retention screws are fully tightened to maintain contact integrity under continuous mechanical vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more