Skip to content

What are you looking for?


You may also like

ABB 10001584 Cable Assembly ST OutputABB 10001584 Cable Assembly ST OutputABB 10001584 Cable Assembly ST Output
ABB 10001584 Cable Assembly ST Output
ABB 10001584 Cable Assembly ST Output
ABB 10001584 Cable Assembly ST Output

ABB 10001584 Cable Assembly ST Output


Only 10 left - Selling fast

PRODUCT SKU : 10001584

PRODUCT TYPE : Cable Assemblies

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for output signal transmission in ABB DCS and PLC automation hardware, the ABB 10001584 (10001584 Cable Assembly) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model 10001584
Brand ABB
Origin Canada
Weight 0.5 lb
Dimensions Standard Cable Assembly Length
Operating Temp -20 to 70 deg C
Power Consumption Passive Component (N/A)
Cable Type ST Output Assembly
Voltage Rating Low Voltage Signal Level

Deterministic Network Integration and I/O Density Scaling

The 10001584 cable assembly routes continuous analog and discrete output channels across distributed I/O racks to optimize signal integrity. High-speed backplane bus communication velocity requires strict shield termination to maintain noise immunity within Profinet and EtherNet/IP deterministic networks. The assembly housing design supports high I/O density scaling inside control enclosures while maintaining full firmware flash compatibility during controller configuration syncs.

Frequently Asked Questions

Q: Does the 10001584 cable assembly support hot-swapping during active I/O operation?

A: No, field wiring connections must be de-energized prior to disconnecting the output cable assembly to prevent signal disruption and electrical arc transients.

Q: How is shield grounding handled on this output cable assembly?

A: Cable shield drain wires must be bonded directly to the low-impedance functional earth ground bar inside the enclosure to suppress high-frequency interference.

Field Installation Guidelines

  • Verify that power to the output module and connected field devices is switched off prior to installing or removing the cable connector.
  • Inspect terminal pins and mating sockets for bent contacts or debris before insertion.
  • Ensure cable strain relief clamps are tightened appropriately to avoid physical tension on individual terminal wires.
  • Route the signal assembly away from high-voltage AC power lines and variable frequency drive outputs to eliminate inductive noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Instrumentation and Control (I&C) Design Basis serves as the foundational technical document for modern plant engineering. Project teams rely on this master specification to govern engineering deliverables across front-end engineering design (FEED) and detailed execution phases. A well-constructed I&C design basis ensures seamless integration among field instrumentation, safety systems, and main control systems. Furthermore, establishing clear technical standards early mitigates execution risks and prevents costly re-engineering during plant commissioning.

Read more
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more