PRODUCT SKU : AAI143-H00/K4A00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-H00/K4A00 from Yokogawa is a robust analog input module designed for distributed control systems. It provides 16 isolated input channels capable of handling 4–20 mA DC signals, ensuring accurate and stable data acquisition in industrial automation environments.

This model supports HART communication, enabling remote diagnostics and transmitter configuration. The suffix codes define its configuration: “H” indicates HART protocol support, “0” denotes the basic type, and “/K4A00” specifies the inclusion of a KS cable interface adapter (ATK4A-00) for connecting to terminal boards.

Technical Specifications

  • Model / Order Number: AAI143-H00/K4A00

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated analog inputs

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: Up to 24 mA

  • Input Resistance:

    • Power ON: 270 Ω (20 mA) to 350 Ω (4 mA)

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Temperature Drift: ±16 µA per 10°C

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0–25.5 V (current limit 25 mA)

  • Isolation Voltage: 1500 V AC between input and system (1 minute)

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS cable

  • Weight: Approx. 0.3 kg

Application Scenarios

  • Signal acquisition from field transmitters in process industries

  • Integration into Yokogawa CENTUM VP and CS 3000 systems

  • Environments requiring HART communication for diagnostics and configuration

  • Safety‑critical monitoring in petrochemical, oil & gas, and power generation

FAQ

Q: How many channels does the AAI143-H00/K4A00 support?  A: It provides 16 isolated analog input channels.

Q: What does the /K4A00 option mean?  A: It indicates the module is supplied with a KS cable interface adapter (ATK4A-00).

Q: Does the module support HART communication?  A: Yes, the “H” suffix confirms HART protocol compatibility.

Q: What is the accuracy of this module?  A: ±16 µA across the rated input range.

Q: Is the module explosion‑proof?  A: No, the suffix “5” specifies that it is a non‑explosion protected type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more