Only 10 left - Selling fast

PRODUCT SKU : AAI143-H00/K4A00

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The AAI143-H00/K4A00 from Yokogawa is a robust analog input module designed for distributed control systems. It provides 16 isolated input channels capable of handling 4–20 mA DC signals, ensuring accurate and stable data acquisition in industrial automation environments.

This model supports HART communication, enabling remote diagnostics and transmitter configuration. The suffix codes define its configuration: “H” indicates HART protocol support, “0” denotes the basic type, and “/K4A00” specifies the inclusion of a KS cable interface adapter (ATK4A-00) for connecting to terminal boards.

Technical Specifications

  • Model / Order Number: AAI143-H00/K4A00

  • Manufacturer: Yokogawa Electric Corporation

  • Type: Analog Input Module

  • Channels: 16 isolated analog inputs

  • Signal Range: 4–20 mA DC

  • Allowable Input Current: Up to 24 mA

  • Input Resistance:

    • Power ON: 270 Ω (20 mA) to 350 Ω (4 mA)

    • Power OFF: ≥500 kΩ

  • Accuracy: ±16 µA

  • Temperature Drift: ±16 µA per 10°C

  • Data Update Period: 10 ms

  • Transmitter Power Supply: 19.0–25.5 V (current limit 25 mA)

  • Isolation Voltage: 1500 V AC between input and system (1 minute)

  • Current Consumption: 230 mA (5 V DC), 540 mA (24 V DC)

  • External Connections: Pressure clamp terminal, MIL connector cable, KS cable

  • Weight: Approx. 0.3 kg

Application Scenarios

  • Signal acquisition from field transmitters in process industries

  • Integration into Yokogawa CENTUM VP and CS 3000 systems

  • Environments requiring HART communication for diagnostics and configuration

  • Safety‑critical monitoring in petrochemical, oil & gas, and power generation

FAQ

Q: How many channels does the AAI143-H00/K4A00 support?  A: It provides 16 isolated analog input channels.

Q: What does the /K4A00 option mean?  A: It indicates the module is supplied with a KS cable interface adapter (ATK4A-00).

Q: Does the module support HART communication?  A: Yes, the “H” suffix confirms HART protocol compatibility.

Q: What is the accuracy of this module?  A: ±16 µA across the rated input range.

Q: Is the module explosion‑proof?  A: No, the suffix “5” specifies that it is a non‑explosion protected type.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more
Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Demystifying Programmable Logic Controllers: Comprehensive Guide to PLC Classification and Selection in Industrial Automation

Modern industrial automation heavily relies on Programmable Logic Controllers (PLCs) to drive factory floor efficiency. Over my 15 years as an industrial automation expert working with DCS, TSI, and control systems, I have seen PLCs evolve into the central nervous system of modern manufacturing. Selecting the right controller requires a deep understanding of PLC types based on physical size, hardware architecture, and power supply configurations.

Read more
Comprehensive Guide to PLC Types in Modern Industrial Automation

Comprehensive Guide to PLC Types in Modern Industrial Automation

Modern industrial automation relies on programmable logic controllers to govern critical factory operations. System integrators classify PLCs based on scale, hardware architecture, and power supply design. Understanding these core categories enables automation engineers to select the right control system architecture. Consequently, proper hardware selection optimizes performance while minimizing long-term operational costs.

Read more