Product Description

The AAI141-H00 analog input module from Yokogawa is designed to provide accurate and stable signal acquisition for distributed control systems. Supporting HART communication, this module offers 16 non-isolated channels for 4–20 mA DC input signals, making it suitable for monitoring transmitters, sensors, and other field devices. Its compact design, fast response, and robust electrical specifications ensure reliable operation in industrial environments.

Technical Specifications

  • Model Number: AAI141-H00

  • Type: 16-Point Analog Input Module

  • Channels: 16 non-isolated input channels

  • Signal Range: 4–20 mA DC

  • Input Current/Voltage: 27 mA, ±7.5 V, ±13 V

  • Accuracy: ±16 µA

  • Input Resistance (Power ON): 400 Ω at 20 mA, 1000 Ω at 4 mA

  • Input Resistance (Power OFF): ≥500 kΩ

  • Data Update Period: 10 ms

  • Step Response Time: 100 ms

  • Temperature Drift: ±16 µA per 10°C change

  • Transmitter Supply Voltage: ≥14.8 V at 20 mA

  • Current Consumption: 310 mA (5 V DC), 450 mA (24 V DC)

  • External Connections: Pressure clamp terminal, KS cable, MIL connector cable

  • Weight: 0.2 kg

  • Communication Protocol: HART-enabled

Key Features

  • Multi-Channel Input: 16 channels for efficient signal acquisition

  • HART Support: Enables digital communication over analog signals

  • Fast Response: 10 ms update cycle with 100 ms step response

  • Compact and Lightweight: Easy integration into control cabinets

  • Stable Accuracy: Maintains precision across varying temperatures

Application Scenarios

  • Process monitoring in chemical and petrochemical plants

  • Power generation and turbine instrumentation

  • Water treatment and distribution systems

  • General industrial automation requiring multi-channel analog input

FAQ

Q: How many channels does the AAI141-H00 provide?  A: It supports 16 non-isolated analog input channels.

Q: Does this module support HART communication?  A: Yes, it is HART-enabled for digital communication over analog signals.

Q: What is the typical accuracy of the input signals?  A: The accuracy is ±16 µA, ensuring precise measurement.

Comparison with Similar Models

  • AAI141-S00: Standard analog input module without HART support

  • AAI141-H00: Enhanced version with HART-enabled communication

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more