Configured for high-accuracy analog signal acquisition in ABB Advant Master process control networks, the ABB DSAI 155 57120001-HZ (DSAI 155 Analog Input Modules) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model DSAI 155
Order Code 57120001-HZ
Brand ABB
Origin Sweden
Product Type Analog Input Modules
Input Signal Type Analog Input Signals
Weight 0.54 kg
Dimensions Standard Advant Master subrack card dimensions
Operating Temp 0 to 55 deg C
Power Consumption Bus-powered via subrack backplane
Customs Tariff Number 85389099
Replaced Product ID 7650055-140

Backplane Bus Communication & I/O Density Scaling

The ABB DSAI 155 analog input board digitizes incoming process signals and streams digitized process values over the internal rack backplane interface to host controllers. The board design supports high I/O density scaling within S100 subracks while preserving signal conversion speed. Factory firmware flash compatibility enables deterministic scan execution across assigned process control nodes.

Frequently Asked Questions

Q: What action is required regarding the backplane interface when replacing a DSAI 155 card?

A: Auxiliary loop and subrack backplane power must be isolated before extracting or inserting the board to prevent logic communication glitches and bus transceiver stress.

Q: How does the DSAI 155 board maintain process signal integrity across the backplane?

A: On-board conditioning filters high-frequency industrial noise before analog-to-digital conversion, ensuring accurate measurement values are written directly to backplane bus registers.

Field Installation Guidelines

  1. Turn off main power to the target I/O subrack prior to inserting or removing the DSAI 155 module.
  2. Carefully align board edge connectors with the subrack guide tracks and insert until the rear plug engages fully into the backplane socket.
  3. Tighten faceplate mounting screws firmly to lock the card into position and secure the ground path to the rack chassis.
  4. Keep analog input cables routed in shielded twisted-pair conduits separate from high-voltage AC lines.
  5. Ground field cable shields at the dedicated cabinet ground bar before applying operational power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Understanding Siemens PLC Memory Cards: MMC, SMC, and SD Solutions in Industrial Automation

Memory management plays a pivotal role in maintaining control system reliability across modern manufacturing plants. Industrial control systems rely on specialized memory cards to store project logic, firmware updates, and retentive system data. Siemens uses several memory architectures, including Micro Memory Cards (MMC) and SIMATIC Memory Cards (SMC). Engineers must understand these hardware variations to ensure zero data loss and minimize downtime during maintenance routines.

Read more
Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Redefining Control Systems: The Rise of Flexible I/O Modules in Industrial Automation

Conventional input-output architectures often limit engineering agility and inflate long-term inventory costs. Today, Flexible Input/Output Modules (FIOM) are transforming how control system engineers design, commission, and maintain automation infrastructure. By allowing individual channel software configuration, FIOM technology bridges the gap between rigid hardware design and dynamic plant requirements.

Read more
Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Understanding Modern SCADA Systems: Architecture, Communication Topologies, and Industrial Applications

Supervisory Control and Data Acquisition (SCADA) systems form the digital backbone of modern industrial automation. They collect critical field data, transmit signals across vast distances, and empower plant operators with real-time process visibility. Across modern infrastructures, SCADA solutions streamline centralized control and maintain continuous operational uptime.

Read more