Skip to content

What are you looking for?


You may also like

51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module
51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module
51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module
51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module

51402497-200 | Honeywell | Experion PKS Digital Output Relay Interface Module


Only 10 left - Selling fast

PRODUCT SKU : 51402457-200

PRODUCT TYPE : Digital Output Relay Interface Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51402497-200 (Model: TP-DSOEP1-100) functions as a high-voltage digital output relay interface within the Experion Process Knowledge System (PKS) architecture. This module isolates and routes high-voltage digital control signals from the controller to field-level actuators, motor starters, and final control elements. It provides an authentic, high-integrity physical interface that safeguards upstream control processors from field electrical transients.

Technical Specifications

Parameter Specification
Brand / Manufacturer Honeywell
Part Number 51402497-200
Model Number TP-DSOEP1-100
System Compatibility Honeywell Experion PKS
Functional Classification Digital output relay interface
Voltage Class High-voltage digital output
Redundancy Configuration Non-redundant
Environmental Protection Protective conformal coating
Dimensions 12.7 × 12.7 × 12.7 cm
Weight Approximately 0.8 kg
Mounting Options Desktop or panel mount
Country of Origin USA
Product Condition 100% Original Brand New
Warranty Period 12 Months

Engineering Advantages

  • Corrosive Environment Mitigation: The factory-applied protective conformal coating shields the internal circuitry against airborne contaminants, moisture, and corrosive gases. This chemical barrier prevents trace degradation and dendrite growth in harsh chemical, oil and gas, or wastewater treatment facilities.

  • High-Voltage Isolation: The integrated physical relays separate low-voltage control logic from high-voltage field execution. This design stops electrical noise, surges, and back-EMF from migrating back into the core Experion PKS controller backbone.

  • Flexible Footprint Deployment: The compact $12.7 \times 12.7 \times 12.7\text{ cm}$ form factor supports both standard panel mounting and temporary desktop testing setups. Engineers can deploy this module in crowded marshaling cabinets without redesigning existing rail layouts.

FAQs

  • Does this module come with factory warranties and original packaging?

    Yes. We supply this product as a 100% original, brand-new unit from factory stock. It includes Honeywell's complete 12-month warranty coverage from the date of purchase.

  • Can I use the 51402497-200 module in a redundant Experion PKS I/O slot?

    No. The TP-DSOEP1-100 features a strictly non-redundant hardware configuration. You must assign it to standard, single-channel non-redundant loops within your Experion PKS system architecture.

  • What specific protection does the conformal coating provide during installation?

    The coating prevents accidental short circuits caused by conductive dust or high humidity during commissioning. However, engineers must still maintain standard ESD grounding protocols and clean panel environments during physical wire termination.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more