Skip to content

What are you looking for?


You may also like

51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card
51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card
51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card
51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card

51401996-100 | Honeywell | TDC 3000 EAMR Application Module Enhanced Redundancy Card


Only 10 left - Selling fast

PRODUCT SKU : 51401996-100

PRODUCT TYPE : Enhanced Redundancy Card

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51401996-100 operates as an Enhanced Application Module Redundancy (EAMR) Assembly Card within the legacy TDC 3000 Distributed Control System (DCS) architecture. This hardware add-on board provides high-speed data mirroring and seamless failover synchronization for the primary Application Module (AM). By continuously cross-checking memory states, the card eliminates single-point-of-failure risks in advanced process optimization networks. We supply this product in 100% Brand New, original factory condition to secure your plant's data integrity and protect complex control configurations from unexpected hardware failure.

Technical Specifications

Parameter Operational Specification Data
Part Number 51401996-100
Manufacturer Honeywell
Board Identifier EAMR Assembly Card
Core Function Enhanced Redundancy Routing for Application Modules
Product Category PLCs / Machine Control (PC Board Add-On Board)
Chassis Compatibility Honeywell TDC 3000 High-Density Slot
Physical Weight 2.07 lbs (0.94 kg)
Communication Sync Speed Deterministic Real-Time Failover Bus
Condition 100% Brand New Original

Engineering Advantages

  • Enforces High-Speed Fault Tolerance: The card establishes an independent, high-bandwidth communication channel between redundant processing pairs. If the primary Application Module crashes, this board executes a deterministic switchover to the backup node in milliseconds, preventing process disruptions in your batch or continuous loops.

  • Neutralizes Industrial Cabinet Signal Noise: Multi-layer board construction and integrated ground shielding insulate the sensitive logic gates from electromagnetic interference (EMI). This heavy-duty shielding guarantees error-free state synchronization even when installed alongside high-current motor starters and switching relays.

  • Simplifies Slide-In Slot Allocation: Designed to slide directly into standard, pre-wired Honeywell TDC 3000 chassis slots, the 2.07 lbs card utilizes native guide rails for mechanical stability. This precise physical alignment prevents terminal pin deformation and minimizes your active installation timeframe.

  • Lowers Thermal Loading via Advanced Substrate Layout: The optimized copper layout and upgraded surface-mount components maximize current distribution efficiency. This lowers localized thermal dissipation on the PCB surface, preventing heat pockets from degrading nearby processor modules in sealed NEMA panels.

FAQs

  • Does this 51401996-100 EAMR board require separate software licenses to activate redundancy features?

    The board provides the physical hardware layer necessary for enhanced redundancy. Your system must run the appropriate Honeywell TDC 3000 software release that supports Application Module redundancy, and you must configure the corresponding node parameters within the system architecture database.

  • Can field technicians hot-swap this card while the primary Application Module executes process logic?

    No. Extracting the active EAMR redundancy card breaks the real-time synchronization link and creates a system error configuration state. Always switch your Application Module cluster into an isolated, non-redundant backup configuration or power down the target slot sequence completely before replacing the board.

  • What preventive measures guarantee proper grounding when seating the card?

    Field engineers must clean the chassis guide rails of any accumulated particulate matter or oxidative scale before insertion. Ensure the board slides completely back until the faceplate mounting screws seat firmly into the metal rack frame, establishing a low-impedance ground path to deflect incoming electrical surges.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more