Skip to content

What are you looking for?


You may also like

51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board
51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board
51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board
51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board

51400926-100 | Honeywell | TDC 3000 Input/Output Interface Board


Only 10 left - Selling fast

PRODUCT SKU : 51400926-100

PRODUCT TYPE : Interface Board

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Honeywell 51400926-100 functions as a high-density, high-integrity Input/Output (I/O) interface board within the Honeywell TDC 3000 Distributed Control System (DCS) framework. This hardware module bridges the gap between field-level transmitters/actuators and the central process manager, executing precise signal conditioning and localized data digitization. We deliver this critical communication link exclusively in 100% brand new, original factory condition to eliminate processing latency, prevent variable drops, and protect raw field data from transmission corruption.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Part/Model Number 51400926-100
Product Type Input/Output (I/O) Control Board
System Compatibility Honeywell TDC 3000 / Experion DCS Systems
Country of Origin United States (USA)
Physical Dimensions 12.7 cm x 12.7 cm x 12.7 cm (5.0" x 5.0" x 5.0")
Net Weight 0.8 kg (1.76 lbs)
Chassis Mounting Layout Specialized Compact Cube Nest Slot Insertion

Engineering Advantages

  • Saves Premium Space via Cubical Geometry: The distinct 12.7 cm x 12.7 cm x 12.7 cm cube configuration provides multi-layer hardware component density. This layout packs extensive I/O processing circuitry into a minimized footprint, resolving spatial limitations inside crowded marshalling cabinets.

  • Neutralizes High-Frequency Plant Floor EMI: Multi-layer ground planes and onboard optocouplers separate the low-voltage microprocessor logic from high-voltage field wiring spikes. This galvanic isolation rejects severe electromagnetic interference (EMI) originating from nearby heavy-duty pumps, switches, and motor drives.

  • Withstands Continuous Cabinet Vibration: Rigid, reinforced structural board edges slide snugly into standard Honeywell enclosure guides. This tight mechanical anchoring system eliminates microscopic board movement, halting friction wear and trace stress caused by plant structural oscillations.

  • Maximizes Enclosure Air Circulating Passages: The symmetric cube structure permits uniform ventilation clearance around the module housing. This dimensional balance prevents thermal pooling inside the slot nest and lowers the operational stress on neighboring controller components.

FAQs

  • Does this I/O board arrive ready to run, or does it require manual firmware configuration before installation?

    The 51400926-100 board contains factory-loaded bootstrap logic. Once you slide the module firmly into its designated chassis nest slot and restore power, the central system processor automatically detects the new hardware ID and pushes the required operational network configuration parameters.

  • Is this board an authentic, factory-fresh Honeywell component or a refurbished unit?

    We guarantee this product is 100% brand new, factory-fresh, and completely unused. It ships in its original manufacturer-sealed anti-static shielding packaging with all native USA quality-assurance tracking barcodes completely intact.

  • What installation guidelines must technicians follow to protect the board from failure?

    Field engineers must isolate power to the target chassis section prior to insertion. Put on a verified, grounded electrostatic discharge (ESD) wrist strap, align the board runners with the plastic slot guides, and push the module smoothly to seat the multi-pin backplane connectors without bending the terminal pins.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more