Skip to content

What are you looking for?


You may also like

3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada
3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada
3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada
3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada

3300/55-01-13-13-00-01 Dual Velocity Monitor Module | Bently Nevada


Only 10 left - Selling fast

PRODUCT SKU : 3300/55-01-13-13-00-01

PRODUCT TYPE : Dual Velocity Monitor Modules

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The 3300/55-01-13-13-00-01 is a specialized dual-channel velocity monitor module designed for the Bently Nevada 3300 Monitoring System. It accepts inputs from compatible velocity transducers to continuously measure and evaluate bearing-housing vibration. This unit provides reliable signal conditioning and configurable alarm processing to protect critical rotating machinery from excessive vibration levels.

Transducer Compatibility and Inputs

This module features a dual-channel input configuration optimized for Velomitor, HTVS, and Velocity Seismoprobe sensors. It conditions the incoming vibration signals to track velocity across a full-scale range of 0 to 2 in/s peak per channel. This direct sensor integration ensures accurate measurement of machinery casing dynamics.

Alarm Processing and Relay Output

The unit includes user-programmable alarm setpoints to establish specific safety thresholds for monitored assets. When vibration levels exceed pre-set limits, the module initiates protection logic through its epoxy-sealed alarm relay option. This configuration helps safeguard industrial equipment by providing reliable alert and danger switching capabilities.

Physical and Environmental Specifications

Engineered for internal rack mounting within standard Bently Nevada 3300 system enclosures, the module connects directly to the rack backplane. It is built to operate reliably in industrial environments with an operating temperature range of 0 deg C to +65 deg C and up to 95 percent non-condensing humidity.

Parameter Specification
Model 3300/55-01-13-13-00-01
Brand Bently Nevada
Number of Channels 2 dual velocity inputs
Compatible Transducers Velomitor, HTVS, Velocity Seismoprobe
Full-Scale Range 0 to 2 in/s peak (each channel)
Resolution +/-1.6% of monitor full-scale
Alarm Setpoints User-programmable
Trip Multiply None
Alarm Relay Option Epoxy-sealed
Operating Temperature 0 deg C to +65 deg C
Storage Temperature -40 deg C to +85 deg C
Humidity 95% non-condensing
Mounting Type Rack-mounted in 3300 system
Dimensions 263 x 58 x 28 mm
Weight 4.3 kg

Frequently Asked Questions

Q: What types of transducers are compatible with the Bently Nevada 3300/55-01-13-13-00-01 module?

A: It is compatible with Velomitor, HTVS, and Velocity Seismoprobe velocity transducers.

Q: What is the full-scale range for each channel on this monitor?

A: The full-scale range is 0 to 2 in/s peak for each of the two channels.

Q: How is the alarm relay configured on this specific model?

A: This unit features an epoxy-sealed alarm relay option designed for reliable switching during alarm conditions.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Traditional industrial automation relies heavily on dedicated input-output (IO) modules. In a standard distributed control system (DCS) or programmable logic controller (PLC) setup, design engineers assign specific cards to distinct signal types. For instance, a traditional 16-channel digital input (DI) card exclusively processes digital signals. However, engineering projects frequently encounter last-minute changes in signal counts. Therefore, discovering a missing analog input (AI) channel late in the design phase forces engineers to purchase and install an entirely new, dedicated AI card. Consequently, this rigidity drives up hardware expenses, wastes cabinet space, and delays commissioning schedules.

Read more
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more