Skip to content

What are you looking for?


You may also like

2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module
2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module
2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module
2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module

2711P-RDK12C | Allen-Bradley PanelView Plus 1250 Display Module


Only 10 left - Selling fast

PRODUCT SKU : 2711P-RDK12C

PRODUCT TYPE : PanelView Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 2711P-RDK12C is a replacement display module designed for the PanelView Plus 1250 family of graphic terminals. It provides a 12.1-inch TFT LCD with resistive touchscreen input and integrated keypad functionality, ensuring reliable operator interface performance in industrial automation systems.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line PanelView Plus 1250

  • Part Number 2711P-RDK12C

  • Category PanelView Terminals

  • Product Family PanelView Plus Graphic Terminals

  • Weight 6.00 lbs (2.72 kg)

  • Description Display module for PanelView Plus 1250 and PanelView Plus 6 1250 terminals

  • Compatibility Touch and keypad versions of PanelView Plus 1250 / PanelView Plus 6 1250

  • Display Type Color active-matrix TFT LCD

  • Display Size 12.1 inches

  • Display Area 246 × 184 mm (9.7 × 7.2 in.)

  • Resolution 800 × 600 pixels (SVGA)

  • Color Depth 18-bit graphics

  • Luminance 300 cd/m²

  • Anti-Glare Overlay Not included

  • Keypad Functions F1–F20, K1–K20, numeric keys, navigation keys

  • Touch Input Analog resistive, rated for 1 million actuations

Application Scenarios

  • Replacement display for PanelView Plus 1250 operator terminals

  • Industrial environments requiring high-visibility operator interfaces

  • Systems needing both keypad and touchscreen input options

FAQ

  • Q: Is this module compatible with PanelView Plus 6 terminals?  A: Yes, it supports both PanelView Plus 1250 and PanelView Plus 6 1250 models.

  • Q: What is the resolution of the display?  A: 800 × 600 pixels with 18-bit color graphics.

  • Q: Does the unit include an anti-glare overlay?  A: No, the anti-glare overlay is not included.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more
Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Comprehensive Guide to Servo Motor Drive Control Techniques in Industrial Automation

Precision motion control systems drive high-throughput manufacturing across modern industrial automation environments. Unlike standard induction motors running on basic variable frequency drives, servo motor systems deliver sub-millimeter positioning accuracy and fast dynamic response.

Read more