Skip to content

What are you looking for?


You may also like

2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable
2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable
2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable
2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable

2711-NC13 | Allen-Bradley PanelView Standard Upload/Download Programming Cable


Only 10 left - Selling fast

PRODUCT SKU : 2711-NC13

PRODUCT TYPE : Programming Cable

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 2711-NC13 serves as the primary communication link for configuring and maintaining PanelView Standard operator terminals. This high-quality RS-232 serial cable facilitates the transfer of application files between a personal computer running PanelBuilder32 software and the HMI hardware. We supply this cable as 100% Brand New original factory stock, ensuring the shielding integrity and pin-to-pin continuity required for error-free data uploads and downloads in electrically noisy industrial environments.

Technical Specifications

Feature Specification
Manufacturer Allen-Bradley / Rockwell Automation
Part Number 2711-NC13
Cable Type RS-232 Serial Programming/Communication
Connector A 9-pin D-sub (Female)
Connector B 9-pin D-sub (Female)
Length 5 Meters (16.4 ft)
Compatibility PanelView 300, 550, 600, 900, 1000, 1400
Protocol Support DF1, DH-485 (via RS-232 port)
Jacket Material Industrial-grade PVC
Weight 0.45 lbs (0.20 kg)

Engineering Advantages

  • Optimized 5-Meter Reach: The 5-meter (16.4 ft) length provides ample distance for technicians to operate a laptop safely outside of high-voltage cabinet zones while connected to the HMI. This extended reach simplifies field commissioning in large-scale control suites.

  • Superior EMI Shielding: The 2711-NC13 incorporates a fully shielded internal braid to protect the serial data stream from electromagnetic interference (EMI) generated by nearby variable frequency drives (VFDs) and motor starters. This prevents packet loss and "time-out" errors during critical firmware updates.

  • Industrial-Grade Molded Strain Relief: Heavy-duty molded connectors prevent wire fatigue at the termination points. This rugged construction allows for frequent connection and disconnection cycles typical of portable maintenance tools used across multiple production lines.

  • Null-Modem Pin Configuration: The cable utilizes a specific internal crossover (Null-Modem) wiring scheme required by the PanelView Standard communication ports. This eliminates the need for external gender changers or "null-modem" adapters, providing a direct "plug-and-play" experience.

  • Gold-Plated Contacts: High-conductivity gold plating on the 9-pin connectors resists oxidation in humid or corrosive industrial atmospheres, ensuring low-resistance electrical contact over the entire lifespan of the cable.

FAQs

  • Can I use the 2711-NC13 with a modern laptop that lacks a serial port?

    Yes, but you must use a high-quality USB-to-RS232 serial adapter (such as the Allen-Bradley 1203-USB or a reputable Prolific/FTDI-based converter) in conjunction with the 2711-NC13 to establish a connection.

  • Is this cable compatible with PanelView Plus terminals?

    The 2711-NC13 targets the PanelView Standard (300 through 1400) series. While PanelView Plus terminals also feature RS-232 ports, they often utilize different cable configurations or Ethernet for programming. Always verify your specific HMI manual for "Upload/Download Cable" requirements.

  • Does this cable support runtime communication between a PLC and HMI?

    Yes. In addition to programming, the 2711-NC13 can serve as a permanent runtime communication link between a PanelView Standard terminal and a SLC 500, MicroLogix, or ControlLogix controller via their respective RS-232 ports.

  • How can I identify an original 2711-NC13 from generic imitations?

    Our 100% Brand New units feature original Rockwell Automation labeling and molded part numbers. Generic cables often lack the proper industrial shielding and specific pin-out required for reliable PanelView communication, which can lead to intermittent connection failures.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more