Skip to content

What are you looking for?


You may also like

1MRK002266-AAr03 ABB Optical Ethernet Module1MRK002266-AAr03 ABB Optical Ethernet Module1MRK002266-AAr03 ABB Optical Ethernet Module
1MRK002266-AAr03 ABB Optical Ethernet Module
1MRK002266-AAr03 ABB Optical Ethernet Module
1MRK002266-AAr03 ABB Optical Ethernet Module

1MRK002266-AAr03 ABB Optical Ethernet Module


Only 10 left - Selling fast

PRODUCT SKU : 1MRK002266-AAr03

PRODUCT TYPE : Optical Ethernet Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 1MRK002266-AAr03 serves as the primary 1MRK002266-AA Optical Ethernet Module utilized to execute optical network interfacing, analog signal sampling, and discrete contact switching across ABB protection and control platforms.

Hardware Specifications

Parameter Specification
Model 1MRK002266-AAr03
Brand ABB
Operating Temp -20 to +70 deg C
Power Consumption 24 VDC Nominal
Analog Inputs 8 channels (0-10 V)
Digital Outputs 16 channels
Response Time < 2 ms
Communication Ports Ethernet, RS485
Protocols Supported Modbus, IEC 61850
Isolation Voltage 2500 V RMS
Electromagnetic Immunity IEC 61000-4 Compliant
Humidity Range 5% to 95% RH, non-condensing

Backplane Bus Communication Velocity & Firmware Flash Compatibility

The module integrates 8 analog input channels and 16 digital output channels onto a single subrack footprint to manage I/O density scaling. Operating on a 24 VDC power supply, internal logic circuits maintain real-time signal conversion with processing response times under 2 ms. High backplane bus communication velocity handles deterministic packet traffic over Ethernet and RS485 physical layers, supporting IEC 61850 and Modbus protocols. Channel-to-ground dielectric protection is maintained up to 2500 V RMS under IEC 61000-4 electromagnetic immunity parameters, preserving system operation and firmware flash compatibility during transient events.

Frequently Asked Questions

Q: What is the isolation rating between field-side interfaces and internal logic circuits on the 1MRK002266-AAr03?

A: The module is rated for 2500 V RMS isolation to protect internal backplane processing elements from external field surges and noise.

Q: What are the input signal limits for the onboard analog input channels?

A: The 8 analog input channels accept a voltage range of 0-10 V with a total signal-to-output response latency of less than 2 ms.

Field Installation Guidelines

  • Disconnect incoming 24 VDC power source feeds prior to inserting or seating the card into the chassis slot.
  • Connect shield drain wires for 0-10 V analog input lines to a designated cabinet ground bar at a single termination point.
  • Ensure RS485 communication lines are terminated with matching 120 ohm resistors at both cable end nodes.
  • Maintain ambient cabinet airflow to ensure operating temperatures stay within the specified -20 to +70 deg C range.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more