PRODUCT SKU : 1794-IA16

PRODUCT TYPE : AC Digital Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1794-IA16 is a FLEX I/O AC digital input module designed to handle 16 non-isolated input channels. It converts AC signals into logic-level inputs for distributed control systems. With DIN rail mounting, multiple terminal base compatibility, and integrated LED indicators for each channel, this module provides reliable input monitoring in industrial automation environments.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line FLEX I/O 1794

  • Product Type AC Digital Input Module

  • Part Number 1794-IA16

  • Weight 0.25 lbs (0.11 kg)

  • Inputs 16 non-isolated channels

  • Terminal Base Compatibility 1794-TB3, 1794-TB3S, 1794-TBN, 1794-TB3K, 1794-TB3SK, 1794-TBNK

  • Keyswitch Position 8

  • On-State Voltage Range 74–132 V AC

  • Off-State Voltage (Max) 20 V AC

  • On-State Current Min 5.49 mA, Max 14.81 mA

  • Off-State Current Min 2.9 mA

  • Nominal Input Current 12 mA @ 120 V AC

  • Flexbus Current 20 mA

  • Power Dissipation 6.4 W @ 132 V AC max

  • Indicators 16 yellow LED status indicators

  • Mounting Style DIN rail

  • Enclosure Type Open-style (no housing)

  • Wire Size Determined by installed terminal base (22–14 AWG typical)

  • Operating Temperature 0–55 °C (32–131 °F)

  • Storage Temperature –40–85 °C (–40–185 °F)

  • Vibration Resistance 5 g @ 10–500 Hz

  • Shock Resistance 30 g

Application Scenarios

  • Monitoring AC input signals in distributed FLEX I/O systems

  • Industrial automation requiring multiple input channels with LED diagnostics

  • Control panels where compact DIN rail modules are preferred

FAQ

Q: How many input channels does the 1794-IA16 provide?  A: It supports 16 non-isolated AC input channels.

Q: What voltage range is supported for ON-state detection?  A: Between 74 V AC and 132 V AC.

Q: Does the module provide input status indication?  A: Yes, each channel has a yellow LED indicator.

Comparable Models

  • 1794-IA16: 16-point AC input module (this model)

  • 1794-IB16: 16-point DC input module

  • 1794-IV16: 16-point DC voltage input module

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more