Skip to content

What are you looking for?


You may also like

1788-MCHKR | Allen-Bradley | Linking Devices Media Checker1788-MCHKR | Allen-Bradley | Linking Devices Media Checker1788-MCHKR | Allen-Bradley | Linking Devices Media Checker
1788-MCHKR | Allen-Bradley | Linking Devices Media Checker
1788-MCHKR | Allen-Bradley | Linking Devices Media Checker
1788-MCHKR | Allen-Bradley | Linking Devices Media Checker

1788-MCHKR | Allen-Bradley | Linking Devices Media Checker


Only 10 left - Selling fast

PRODUCT SKU : 1788-MCHKR

PRODUCT TYPE : Linking Devices Media Checker

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1788-MCHKR serves as an essential handheld diagnostic tool for industrial network maintenance and commissioning. This versatile media checker rapidly identifies cable failures and measures wire length across multiple industrial protocols, including Ethernet, ControlNet, DeviceNet, DH+, and RIO. Powered by two standard AA alkaline batteries, it delivers up to 50 hours of continuous operation in the field. We supply this item as a 100% Brand New, factory-sealed unit.

Part Number Breakdown

  • 1788: Identifies the 1788 Linking Devices product family.

  • MCHK: Denotes the Media Checker function.

  • R: Specifies the hardware revision or regional variant.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Type Handheld Media Checker
Supported Networks Ethernet, ControlNet, DeviceNet, DH+, RIO
Input Connectors RJ45, DB-9, BNC
Ethernet Cable Range 1 - 350 meters
Ethernet Resolution 0.5 meters
ControlNet Cable Range 1 - 650 meters
Display Interface 2-Line, 16-Character LCD
Power Requirements Two AA 1.5V Alkaline Batteries
Typical Battery Life 50 hours
Operating Temperature 0°C to +45°C

Engineering Advantages

Multi-Protocol Network Diagnostics
The 1788-MCHKR simplifies field maintenance by supporting a wide array of legacy and modern industrial networks. Technicians can use a single device to troubleshoot Ethernet (UTP/FTP), ControlNet (RG6/RG6F), DeviceNet (Thick/Thin), and legacy DH+/RIO cables. This versatility eliminates the need to carry multiple specialized testers, reducing toolbag weight and streamlining troubleshooting workflows.

Precise Cable Fault Detection and Length Measurement
This media checker accurately detects common cable failures such as opens, shorts, and miswires. It provides precise length measurements with a 0.5-meter resolution for Ethernet cables up to 350 meters and ControlNet cables up to 650 meters. Knowing the exact location of a fault or the total length of a cable run helps engineers quickly replace damaged sections and verify compliance with network physical layer specifications.

Rugged Portable Design
Designed for the demanding industrial environment, the 1788-MCHKR operates reliably in temperatures ranging from 0°C to 45°C. Its handheld form factor and intuitive interface—featuring Enter, Up, Down, and Setup buttons alongside a clear 16-character LCD—allow technicians to perform rapid wire mapping and continuity tests directly on the factory floor without needing a laptop or external power source.

FAQs

Q: Which types of industrial cables can the 1788-MCHKR test?
A: This media checker supports a broad range of cables. It tests Ethernet (UTP/FTP), ControlNet (RG6, RG6F, DS3/4), DeviceNet (Thick, Thin, KwikLink), and legacy DH+/RIO cables (1770-CD, 9022, 9463).

Q: How accurate is the cable length measurement?
A: For Ethernet cables, the device offers a high resolution of 0.5 meters. It can measure Ethernet cable lengths from 1 to 350 meters and ControlNet cable lengths from 1 to 650 meters, helping you pinpoint faults with high precision.

Q: What kind of power source does the 1788-MCHKR use?
A: The unit is powered by two standard AA 1.5V alkaline batteries. These provide excellent portability and typically last for about 50 hours of typical operation, ensuring the tool is ready for full-day field use.

Q: What connectors are available on the device?
A: The media checker is equipped with versatile input connectors to match various industrial cables, including an RJ45 jack for Ethernet, a DB-9 port for DeviceNet/DH+/RIO, and a BNC connector for ControlNet coaxial cables.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more