PRODUCT SKU : 1783-BMS10CL

PRODUCT TYPE : Ethernet Switch

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The 1783-BMS10CL from Allen-Bradley is a high-performance managed Ethernet switch designed for industrial networking. Part of the Stratix 5700 series, it provides secure, reliable connectivity for complex automation and control systems. Its robust construction and flexible port options make it ideal for harsh industrial environments.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: Stratix 5700

  • Part Number: 1783-BMS10CL

  • Module Type: Managed Ethernet Switch

  • Ports: 10 total

    • RJ45 Ports: 8

    • Combo Ports (RJ45/SFP): 2

  • Input Voltage Range: 12–48 VDC

  • Compatible Memory Card: 1784-SD1

  • Weight: 2.88 lbs (1.30 kg)

  • UPC: 886739973477

Features

  • Flexible Connectivity: 8 standard RJ45 ports and 2 combo ports for fiber or copper connections.

  • Industrial Reliability: Designed to operate under extreme industrial conditions with stable network performance.

  • Network Management: Supports VLAN, QoS, and other managed switch capabilities for secure traffic control.

  • Compact Design: Lightweight and easy to install within control panels or network racks.

Applications

  • Medium to large-scale industrial Ethernet networks.

  • PowerFlex or ControlLogix PLC systems requiring reliable communication.

  • Factory automation requiring managed and secure Ethernet traffic.

FAQ

Q: Which memory card is compatible with 1783-BMS10CL?
A: Compatible with Allen-Bradley 1784-SD1 memory cards.

Q: How many total Ethernet ports are available?
A: 10 ports, including 8 RJ45 and 2 combo ports.

Q: What is the input voltage range?
A: 12–48 VDC, suitable for standard industrial power sources.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more