Overview

The 1747-M13 by Allen-Bradley is a high-performance memory module designed for the SLC 500 series PLC systems. It offers reliable program and data table storage with fast scan times, supporting both fixed and modular hardware configurations. Compact and lightweight, this module integrates seamlessly into SLC 500 setups.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: SLC 500

  • Part Number: 1747-M13

  • Module Type: Memory Module

  • Compatible Processors: SLC 5/03, SLC 5/04, SLC 5/05

  • User Memory Capacity: 64 KB (64,000 words)

  • Program Scan Time: 0.9 ms

  • I/O Scan Time: 0.225 ms

  • Communication Ports: Ethernet, RS-232

  • Backup Memory: Flash

  • Compatible Adapter: 1747-M15 Series B

  • I/O Chassis Requirement: 3

  • Chassis Module Slots: 30

  • Configuration Method: PROM Programmer

  • Installation: Processor PC Board

  • Weight: 0.06 lbs (0.03 kg)

Features

  • Fast Program Execution: Low program scan and I/O scan times for real-time operation.

  • Versatile Compatibility: Works with multiple SLC 500 processors and supports both fixed and modular hardware.

  • Reliable Data Storage: Flash backup ensures program safety and quick retrieval.

  • Compact & Lightweight: Minimal footprint in PLC systems for easy integration.

Applications

  • SLC 500 PLC systems requiring program and data table storage.

  • Industrial automation setups with modular or fixed hardware.

  • Backup memory solution for critical process control applications.

FAQ

Q: What processors are compatible with the 1747-M13?
A: It supports SLC 5/03, 5/04, and 5/05 processors.

Q: Can this module be used with a 1747-M15 adapter?
A: Yes, it is compatible with the 1747-M15 Series B adapter.

Q: How much memory does it provide?
A: Provides 64 KB user memory (64,000 words).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more