Skip to content

What are you looking for?


You may also like

1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module
1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module
1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module
1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module

1746-NIO4V | Allen-Bradley SLC 500 Analog Combination Module


Only 10 left - Selling fast

PRODUCT SKU : 1746-NI04V

PRODUCT TYPE : Analog Combination Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1746-NIO4V is an analog combination module for the SLC 500 series, designed to handle both voltage and current signals. It provides two differential analog inputs and two non-isolated voltage outputs, making it suitable for applications requiring precise signal conversion and control. With high resolution, fast update times, and rack-mount compatibility, it ensures reliable performance in industrial automation systems.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Category PLCs

  • Product Line SLC 500

  • Part Number 1746-NIO4V

  • Weight 1.00 lbs (0.45 kg)

  • Module Type Analog combination module

  • Inputs 2 differential voltage/current inputs

  • Current Input Range -20 to +20 mA

  • Current Input Resolution 1.22070 µA per LSB

  • Voltage Input Range -10 to +10 VDC

  • Voltage Input Resolution 305.176 µV per LSB

  • Outputs 2 non-isolated voltage outputs

  • Output Voltage Range -10 to +10 VDC

  • Output Voltage Resolution 1.22070 mV per LSB

  • Resolution 16-bit input, 14-bit output

  • Bandwidth 10 Hz

  • Update Time 512 µs

  • Step Response 60 ms (input), 2.5 ms (output)

  • Backplane Current (5 VDC) 55 mA

  • Backplane Current (24 VDC) 115 mA

  • Mounting Rack mount

  • Slot Width 1

Application Scenarios

  • Signal conversion for process control systems

  • Industrial automation requiring precise analog input/output handling

  • Applications needing fast update times and high-resolution data acquisition

  • Integration into SLC 500 racks for mixed analog/digital control

FAQ

Q: How many inputs and outputs does the 1746-NIO4V provide?  A: It offers 2 differential analog inputs and 2 non-isolated voltage outputs.

Q: What is the resolution of the inputs and outputs?  A: Inputs are 16-bit resolution, while outputs are 14-bit resolution.

Q: What is the typical update time?  A: The module updates in 512 microseconds, with a step response of 60 ms for inputs and 2.5 ms for outputs.

Comparison with Similar Models

  • 1746-NI4: Provides only analog inputs, no outputs.

  • 1746-NO4V: Provides only analog voltage outputs.

  • 1746-NIO4V: Combination module with both inputs and outputs for flexible applications.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Designing Robust SCADA Systems for Electrical Substation Automation

Designing Robust SCADA Systems for Electrical Substation Automation

Electrical substation automation requires rigorous engineering standards to guarantee uninterrupted power distribution and grid stability. Therefore, control engineers must design supervisory control and data acquisition (SCADA) architectures with absolute precision. In my 15 years of commissioning power protection and substation automation systems, I have witnessed how meticulous SCADA design prevents catastrophic grid failures. Below, I outline the critical engineering practices required to build reliable substation SCADA solutions.

Read more
Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Demystifying Earthing, Grounding, and Bonding in Industrial Process Plants

Industrial automation networks, power distribution systems, and complex control loops rely heavily on proper grounding to maintain operational integrity. Therefore, control engineers and electrical specialists must thoroughly understand the distinctions between earthing, grounding, and bonding. In my 15 years of commissioning distributed control systems (DCS) and factory automation architectures, I have encountered numerous mysterious equipment failures caused by improper grounding practices. Below, I clarify these essential concepts and outline the industry standards governing industrial electrical safety.

Read more
Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Empowering Predictive Maintenance in PLC and SCADA Systems Through Maintenance Management

Industrial automation networks constantly generate vast streams of diagnostic data before major equipment failures occur. Therefore, integrating control systems with maintenance management platforms is essential for maximizing plant uptime. In my 15 years of commissioning programmable logic controllers (PLCs) and supervisory control and data acquisition (SCADA) networks, I have witnessed how raw alarms sit unnoticed in controller buffers. Bridging the gap between automation software and computerized maintenance management systems (CMMS) transforms early warning signals into actionable work orders. Below, I examine how this integration drives predictive maintenance across modern industrial facilities.

Read more