Skip to content

What are you looking for?


You may also like

05704-A-0146 | Honeywell | System 57 Fire Control Card05704-A-0146 | Honeywell | System 57 Fire Control Card05704-A-0146 | Honeywell | System 57 Fire Control Card
05704-A-0146 | Honeywell | System 57 Fire Control Card
05704-A-0146 | Honeywell | System 57 Fire Control Card
05704-A-0146 | Honeywell | System 57 Fire Control Card

05704-A-0146 | Honeywell | System 57 Fire Control Card


Only 10 left - Selling fast

PRODUCT SKU : 05704-A-0146

PRODUCT TYPE : Fire Control Cards

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 05704-A-0146, also cataloged as the 05704-A-0146 (5704F Fire Control Card), operates as a dedicated hardware component for multi-zone flame detection signal processing and safety alarm contact actuation within System 57 rack enclosure assemblies.

Hardware Specifications

Parameter Specification
Model 05704-A-0146 (5704F)
Brand Honeywell
Origin USA
Weight 0.16 kg
Dimensions 17.2 cm x 2.5 cm x 13.2 cm
Operating Temp -0 deg C to +55 deg C
Power Consumption 7.5 W maximum
Fire Zone Inputs 4 dedicated fire zone input channels
Switched Outputs 2 switched DC power outputs
Remote Input Single 3-function remote input terminal
Relay Capacity Up to 16 configurable relay outputs

Channel-to-Channel Isolation & Galvanic Field Barriers

The 5704F card utilizes optoelectronic channel-to-channel isolation on all 4 fire zone inputs to decouple field device signals from internal backplane microprocessor buses. This galvanic isolation prevents potential ground loop spikes, high-voltage field transients, and electromagnetic interference from disturbing logic execution. Integrated cold junction compensation and noise filtering circuits maintain stable loop voltage regulation across long cable runs connected to flame detectors, ensuring precise threshold detection without false trips.

Frequently Asked Questions

Q: Can the 05704-A-0146 control card be inserted into or removed from the System 57 rack while powered?

A: Hot-swapping the 05704-A-0146 card is not recommended during active operation without isolating the output relays, as power interruption to switched DC outputs will trigger fault states or inadvertent fire suppression system discharges.

Q: What is the maximum current capacity for the 2 switched DC outputs?

A: The switched DC outputs deliver up to 500 mA per channel at system operating voltage and include internal current-limiting protection against short circuits across field wiring runs.

Field Installation Guidelines

  1. Card Insertion: Align the card edge connector with the designated 19-inch rack slot guide rails and push firmly until the rear backplane connector fully seats. Tighten the two front panel captive retention screws to ensure chassis earth continuity.
  2. Wiring Isolation: Route field input connections separately from AC power supply distribution cables and high-inductance relay drive wiring to prevent capacitive coupling.
  3. Shield Termination: Terminate field cable drain wires at the main rack grounding bus bar. Ensure the sensor side of shield wiring is isolated to eliminate circulating ground currents.
  4. Relay Logic Verification: Verify all DIP switch configurations for the 16 relay outputs and ensure proper termination of line end-of-line (EOL) resistors prior to commissioning.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more