Product Details

Description

The CI873A 3BSE092695R1 is a deterministic CIP gateway for AC 800M, supporting cyclic process data and acyclic parameterization. It mounts on the CEX-Bus for low-latency, reliable communication and supports full hardware redundancy for uninterrupted operation in critical industrial environments.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Switzerland

  • Model Number: CI873A (3BSE092695R1)

  • Product Type: EtherNet/IP / DeviceNet Interface

  • Protocol Support: EtherNet/IP (Scanner), DeviceNet (via LD 800DN)

  • Hardware Interface: CEX-Bus (Communication Expansion)

  • Ethernet Ports: 1 x RJ45 (10/100 Mbit/s)

  • Connection Capacity: Up to 128 CIP connections

  • Redundancy: Supports 1:1 hardware redundancy

  • Power Supply: 24 VDC (internal via CEX-Bus)

  • Weight: 0.55 kg

Features

  • Advanced CIP Integration: Enables efficient control and monitoring of a broad spectrum of EtherNet/IP-compliant hardware using standardized protocols.

  • Redundant Reliability: Engineered for high-availability systems, supporting secondary module backup to eliminate single points of failure.

  • Deterministic Signal Updates: Provides the consistent scan times required for precision control of high-speed industrial processes.

  • Comprehensive Diagnostics: Supports acyclic data transfer for remote device configuration, detailed fault analysis, and predictive maintenance.

  • Internalized Power Architecture: Draws required power directly from the controller expansion bus, simplifying cabinet wiring and reducing external dependencies.

  • Industrial Status Indicators: Features front-panel LED displays for real-time monitoring of module health, power status, and network activity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more
Evolving SCADA System Architectures in Industrial Automation

Evolving SCADA System Architectures in Industrial Automation

A robust Supervisory Control and Data Acquisition (SCADA) system serves as the heartbeat of modern industrial operations. Understanding SCADA system architecture is vital for engineers designing efficient control systems. These architectures have evolved from isolated, monolithic structures to highly interconnected, networked ecosystems. Choosing the right design requires balancing data visibility, processing power, and long-term scalability requirements.

Read more
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Selecting the optimal control architecture is a foundational decision in industrial automation. Engineers must frequently choose between a Programmable Logic Controller (PLC) and a dedicated Motion Controller. While both systems manage machinery, their underlying design philosophies differ significantly, impacting performance, scalability, and system integration.

Read more