Skip to content

What are you looking for?


You may also like

ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)
ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)
ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)
ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)

ABB 1VCF751021R802 MAIN BOARD 5 (BASIC)


Only 10 left - Selling fast

PRODUCT SKU : 1VCF751021R802

PRODUCT TYPE : Main Boards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for core logic processing and control execution in ABB protection relay assemblies, the ABB 1VCF751021R802 (1VCF751021R802 MAIN BOARD 5 (BASIC)) provides direct physical/electrical execution. It coordinates internal data bus operations, executes protective algorithm routines, and interfaces directly with human-machine display panels and auxiliary input/output hardware.

Hardware Specifications

Parameter Specification
Model 1VCF751021R802 (MAIN BOARD 5 BASIC)
Brand ABB
Origin Malaysia
Product Type Main Boards
Net Weight 0.27 kg
Dimensions Standard internal relay slot / rack mounting size
Operating Temp -10 to +55 deg C (standard enclosure ambient)
Power Consumption Powered via internal subrack auxiliary supply bus
Replacement Part ID 1VCR014629802 (Main Board 6)
Coating Option DNV-coating applicable with code 1MRS090010
Environmental Compliance Product Not in WEEE Scope

Firmware Flash Compatibility and Module Replacement Hardware Constraints

The main board manages deterministic backplane communication velocity and internal bus routines across relay functional sub-assemblies. Operational execution relies on loading the exact software version indicated on the physical relay side rating plate. In hardware migration scenarios where Main Board 5 is replaced by Main Board 6 (1VCR014629802), hardware compatibility mandates simultaneous replacement of the enclosure top panel (compatible top panel part numbers include 1VCF750153001 through 1VCF750153006, 1VCF750099001 through 1VCF750099006, and 1VCF750165001 through 1VCF750165002). Marine or offshore installations require applying the optional DNV-coating treatment (1MRS090010) to preserve environmental resilience.

Frequently Asked Questions

Q: What hardware modifications are required when migrating from Main Board 5 (1VCF751021R802) to Main Board 6 (1VCR014629802)?

A: Replacing Main Board 5 with Main Board 6 requires replacing the top panel assembly with a compatible top panel code (such as 1VCF750153001-006, 1VCF750099001-006, or 1VCF750165001-002) to maintain proper mechanical and physical alignment.

Q: How is correct software compatibility verified prior to board installation?

A: Software requirements must be cross-referenced directly against the software version printed on the rating plate located on the side frame of the relay enclosure.

Q: How is the board prepared for DNV-certified marine environments?

A: Marine DNV applications require ordering the supplementary DNV-coating process under part code 1MRS090010 alongside the main board hardware.

Field Installation Guidelines

  1. Power Disconnection: Isolate all auxiliary supply power and current transformer secondary inputs before opening the relay chassis or handling the internal main board.
  2. Anti-Static Handling: Wear a properly grounded Electrostatic Discharge (ESD) wrist strap attached to unpainted panel metal when removing or inserting the printed circuit board assembly.
  3. Mechanical Alignment: Align board edge card contacts accurately into the internal rack connectors. Tighten retaining screws to establish low-impedance ground paths across the mounting posts.
  4. Shielding and Wiring Integrity: Verify that all internal ribbon and multi-pin connectors are fully seated and locked. Ensure cabinet signal cabling shields remain connected to the central station earth bus bar.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more