Product Details

The ABB HIEE300890R0001, also cataloged as the LD MUB-01 Measurement Unit Board, operates as a dedicated hardware component for analog signal acquisition and excitation voltage sensing within ABB excitation and drive system architectures.

Hardware Specifications

Parameter Specification
Model LD MUB-01
Part Number HIEE300890R0001
Type Designation UA C383 AE101 / LD MUB-01
Brand ABB
Product Type Circuit Boards / Measurement Unit Boards
Origin Switzerland
Weight 0.1 kg
Dimensions 2.2 cm x 12.4 cm x 12.6 cm
Operating Temp 0 to +55 deg C
Power Consumption Standard internal bus-powered

Backplane Bus Interfacing and System Compatibility

The LD MUB-01 unit board connects directly to internal rack card guides to ensure firmware flash compatibility and real-time data exchange across system backplanes. Trace layouts on the printed circuit board maintain signal integrity during high-frequency sampling routines, preventing inter-channel noise coupling. Integrated edge contacts interface directly with sub-rack backplanes to support high backplane bus communication velocity and stable power routing across processing slots.

Frequently Asked Questions

Q: How is primary operational power provided to the LD MUB-01 card?

A: Electrical power is drawn directly from the system sub-rack backplane upon proper pin connector seating.

Q: What precautions should be observed when replacing the HIEE300890R0001 board?

A: Personnel must adhere to ESD protection standards, including using grounded wrist straps, and ensure the host system is fully powered down prior to physical insertion.

Q: Does the LD MUB-01 card require manual address jumper configuration?

A: Addressing and system parameters are determined by the host controller platform via internal backplane configuration routines upon initialization.

Field Installation Guidelines

  1. De-energize the host cabinet and verify zero voltage status before attempting module insertion or removal.
  2. Wear an grounded ESD wrist strap connected to cabinet earth ground during handling of the bare circuit card.
  3. Slide the 0.1 kg board into designated rack guide slots until the edge connector contacts the backplane receptacle.
  4. Apply even forward pressure on the front edge of the card to fully engage backplane pins without bending contacts.
  5. Secure all panel retention hardware to ensure mechanical grounding continuity across the sub-rack frame.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more