PRODUCT SKU : 3BHB017688R0001

PRODUCT TYPE : Power Supply Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB 3BHB017688R0001, also cataloged as the 3BHB017688R0001 Isolated Power Supply, operates as a dedicated hardware component for galvanic isolation and DC voltage conversion within ABB control cabinets and drive system architectures. Converting a wide-range AC input of 90-264 VAC into a regulated 24 VDC output at 1 A continuous load, the unit delivers stable power while maintaining galvanic separation across system power buses.

Hardware Specifications

Parameter Specification
Model 3BHB017688R0001
Brand ABB
Weight Shipping Weight: 3 kg
Dimensions 100 x 60 x 25 mm
Operating Temp Standard Control Panel Ambient (-20 to 60 deg C)
Power Consumption Load-dependent / 24 W Output Rating
Input Voltage Range 90-264 VAC
Output Voltage 24 VDC
Output Current 1 A
Output Ripple <1%
Isolation Voltage 3000 VRMS

Backplane Power Isolation and Deterministic Power Rails

The 3BHB017688R0001 provides high galvanic isolation rated at 3000 VRMS to prevent ground loop currents and transient voltage spikes from propagating between field power sources and logic control buses. By suppressing output voltage ripple below 1%, the assembly maintains stable power conditions for attached backplane communication interfaces and sensor loops. This clean DC rail preserves firmware flash compatibility and prevents communication drops on Profinet / EtherNet/IP deterministic networks during line supply fluctuations.

Frequently Asked Questions

Q: What protection does the 3000 VRMS isolation specification provide in field applications?

A: The 3000 VRMS galvanic isolation protects internal processing electronics and backplane buses from high-voltage surges, fault currents, and ground loops originating on the AC input lines.

Q: How does the output ripple specification impact sensitive automation I/O loops?

A: An output ripple held under 1% ensures clean 24 VDC power, preventing signal noise or measurement drift on connected analog transducers and controller backplane logic cards.

Q: What input AC line limits are supported by the integrated power conversion stage?

A: The internal switching circuitry accepts a universal single-phase AC input range from 90 VAC to 264 VAC without requiring physical jumper reconfigurations.

Field Installation Guidelines

  1. Power Lockout: Disconnect and lock out the main AC input source before making any wiring connections to the power supply terminals.
  2. Clearance and Airflow: Mount the unit on a standard panel surface or rail assembly maintaining adequate vertical clearance above and below the module to allow convection thermal dissipation.
  3. Terminal Wiring: Crimp wire ferrules onto incoming AC lines and outgoing 24 VDC cables before securing them into screw terminals to ensure low contact resistance.
  4. Protective Earth Grounding: Secure a low-impedance ground wire to the designated PE grounding terminal to enable surge suppression and isolation shielding functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more