The ABB 1MRK002246-BB, also cataloged as the 1MRK002246-BB Power Supply Board, operates as a dedicated hardware component for auxiliary AC-to-DC power conversion within ABB control and protection platforms.

Hardware Specifications

Parameter Specification
Model 1MRK002246-BB
Brand ABB
Weight Approximately 1.52 kg
Dimensions 74 mm x 370 mm x 361 mm
Operating Temp -25 to +70 deg C (Standard Industrial Range)
Power Consumption Self-Consuming Power Conversion Assembly
Input Voltage 100-240 VAC
Output Voltage 24 VDC
Output Current Up to 40 A
Efficiency Up to 90%

Backplane Bus Communication Velocity & I/O Density Scaling

The power supply board steps down wide-range AC mains inputs (100-240 VAC) to a regulated 24 VDC bus output capable of delivering currents up to 40 A at 90% power conversion efficiency. Maintaining voltage bus stability under fluctuating AC primary power ensures high backplane bus communication velocity and continuous logic execution during maximum I/O density scaling. Integrated voltage clamping maintains firmware flash compatibility across backplane processors, preventing processor reset cycles caused by line transient dips.

Frequently Asked Questions

Q: What is the primary output power capacity of the 1MRK002246-BB board?

A: The board provides a regulated 24 VDC output supplying continuous current up to 40 A.

Q: Does the 1MRK002246-BB power supply support universal AC mains input ranges?

A: Yes, the onboard conversion circuit accepts an AC input voltage range from 100 VAC to 240 VAC.

Field Installation Guidelines

  • Isolate all AC primary mains feeders before mounting or removing the power supply card from the enclosure frame.
  • Ensure protective earth grounding terminal connections are fully secured to prevent high-voltage transient coupling.
  • Allow sufficient vertical clearance around chassis cooling vents to permit passive convection heat dissipation during full 40 A load operations.
  • Torque module terminal screws to specified engineering limits to prevent loose connections under mechanical vibration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more