Product Details

The ABB DSRF 170 57310255-AC serves as the primary DSRF 170 Equipment Frame utilized to execute structural module housing and backplane power distribution across MasterPiece platforms. The subrack provides direct physical alignment and multi-slot retention rails for active electronic plug-in cards, keeping internal wiring paths mechanically bound within exact tolerances.

Hardware Specifications

Parameter Specification
Model DSRF 170
Brand ABB
Product ID 57310255-AC
Origin Sweden
Weight 8.0 kg net
Dimensions Standard subrack layout (Optimized for standard industrial cubicle mounting)
Operating Temp 0 to +55 deg C (Standard environment baseline)
Power Consumption Passive chassis architecture (Distributes localized power rail loads)
Core Function Circuit board orientation, mechanical card slot retention, and backplane tracking
Construction Type Open subrack frame configuration

Deterministic Networks & I/O Density Scaling

The structural footprint dictates the physical capacity boundary for localized I/O density scaling inside the automation cubicle. Circuit traces within the integrated backplane coordinate digital packets over Profinet / EtherNet/IP deterministic networks by ensuring structural trace impedance matching. This multi-slot structural layout prevents geometric deflection of rear connector pins, preserving deterministic data scan cycles and maintaining firmware flash compatibility handshakes between adjacent active processing elements.

Frequently Asked Questions

Q: Does the structural layout of the DSRF 170 allow live hot-swap execution of active cards?

A: The DSRF 170 is a passive mechanical enclosure with bus infrastructure. Live component extraction or insertion dependencies reside purely on the active electrical modules and terminal interfaces configured inside the subrack.

Q: How is the common reference potential bonded across separate card slots on the chassis?

A: Frame structural pieces are mechanically bridged to a copper grounding block located at the rear of the assembly. This terminal must be linked to the primary enclosure earth to establish common grounding paths.

Q: What physical faults result from unexpected mechanical warping of the module rails?

A: Mechanical distortion of the guide tracks causes uneven contact terminal stress at the backplane interface, increasing capacitance variation and causing signal packet drops across the internal communications network.

Field Installation Guidelines

  • Bolt the frame housing securely onto the cabinet matrix assembly, verifying parallel plane orientation to prevent mechanical strain on the subrack components.
  • Maintain an open vertical clearance zone of at least 100 mm above and below the chassis border to allow free thermal air draft flow from active circuits.
  • Establish a distinct low-impedance connection between the primary chassis ground stud and the master enclosure copper earth bar using a heavy-gauge braid before powering active components.
  • Ensure all card retention fasteners are manually secured after card insertion to damp mechanical vibration components in long-term operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more