Skip to content

What are you looking for?


You may also like

ABB TC514V2 3BSE013281R1 Communication ModuleABB TC514V2 3BSE013281R1 Communication ModuleABB TC514V2 3BSE013281R1 Communication Module
ABB TC514V2 3BSE013281R1 Communication Module
ABB TC514V2 3BSE013281R1 Communication Module
ABB TC514V2 3BSE013281R1 Communication Module

ABB TC514V2 3BSE013281R1 Communication Module


Only 10 left - Selling fast

PRODUCT SKU : TC514V2 3BSE013281R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB TC514V2 3BSE013281R1, also cataloged as the TC514V2 Communication Module, operates as a dedicated hardware component for converting Advant Fieldbus 100 electrical signals to optical fiber medium within ABB Advant Master process control networks.

Hardware Specifications

Parameter Specification
Model TC514V2 3BSE013281R1
Brand ABB
Origin Sweden
Weight 0.34 kg
Dimensions 58 mm x 168 mm x 122 mm
Operating Temp Standard Cabinet Ambient (0 to 55 deg C)
Power Consumption 24 VDC Control Supply
Interface Type AF 100 Twisted Pair to Optical Fiber Modem / Repeater
Rated Isolation 50 V
System Compatibility ABB Advant Master Process Control System

Deterministic Network Integration and Backplane Communication Velocity

The TC514V2 optical repeater converts physical twisted-pair signals to fiber media while preserving AF 100 bus communication velocity across deterministic networks. By establishing a galvanic isolation barrier rated at 50 V, the unit prevents ground loops and electrical interference from disrupting remote I/O density scaling. The module maintains full firmware flash compatibility across connected controller nodes, ensuring deterministic cycle times and synchronization across extended topology runs.

Frequently Asked Questions

Q: What power input is required to operate the TC514V2 repeater?

A: The module requires a nominal 24 VDC external control power supply for internal signal processing and optical transceiver operation.

Q: What isolation rating is provided between the electrical bus interface and internal circuits?

A: The device features a rated isolation voltage of 50 V to protect the AF 100 network segment from common-mode voltage spikes.

Q: How does switching from electrical to optical media affect network deterministic execution?

A: Optical signal conversion introduces negligible propagation delay, preserving deterministic network timing and scan cycle synchronization across AF 100 fieldbus nodes.

Field Installation Guidelines

  • Disconnect external 24 VDC power before wiring electrical terminals or seating the module into the mounting assembly.
  • Maintain minimum bend radius limits for fiber optic cables to avoid optical signal attenuation and packet loss.
  • Ensure twisted-pair shielding is grounded at specified single-point earth terminations according to AF 100 cable installation rules.
  • Mount the module vertically to facilitate natural convective heat dissipation across the enclosure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more