ABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link ModuleABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link ModuleABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link Module
ABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link Module
ABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link Module
ABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link Module

ABB RLM 02 3BSE091723R1 PROFIBUS Redundancy Link Module


Only 10 left - Selling fast

PRODUCT SKU : RLM 02 3BSE091723R1

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for PROFIBUS line redundancy in industrial communication architectures, the ABB RLM02 3BSE091723R1 (RLM02 Communication Module) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model RLM02 3BSE091723R1
Brand ABB
Origin Standard ABB Manufacturing
Weight 0.46 kg
Dimensions 175.5 mm x 103.5 mm x 90 mm
Operating Temp 0 to +60 deg C (Standard Industrial Range)
Power Consumption 24 VDC Auxiliary Supply Input
Interface Type RS485 Physical Layer
Bus Protocol PROFIBUS DP
Line Conversion 1 Non-Redundant Line to 2 Redundant RS485 Lines (and vice versa)
Environmental Compliance EU Directive 2011/65/EU (RoHS)
Marine Certification Germanischer Lloyd (GL) Cat. A, B, C, D (Requires 3BDZ000397R1 Filter)

Backplane Bus Communication Velocity & Deterministic Networks

The RLM02 converts a single non-redundant PROFIBUS line into two parallel, line-redundant RS485 channels to ensure deterministic networks without data loss. Internal signal-shaping circuits process incoming serial frames to preserve backplane bus communication velocity and transmission waveform integrity. Automatic line monitoring maintains continuous bus availability, switching copper physical paths upon detecting line errors or signal attenuation. Full firmware flash compatibility ensures direct integration with standard PROFIBUS master and slave nodes across System 800xA and S800 I/O architectures.

Frequently Asked Questions

Q: What is required to satisfy Germanischer Lloyd (GL) marine certification for the RLM02 module?

A: Marine certification under GL Categories A, B, C, and D requires the installation of an external power supply filter (ABB Part Number 3BDZ000397R1) on the incoming power feed.

Q: How does the RLM02 manage PROFIBUS signal conversion?

A: The module operates bi-directionally on the RS485 physical layer, converting one standard PROFIBUS channel into two redundant PROFIBUS RS485 lines and vice versa without protocol translation delays.

Field Installation Guidelines

  • Mount the module securely on a grounded DIN rail inside a protective cabinet enclosure.
  • Install the 3BDZ000397R1 power supply filter in series with the incoming 24 VDC supply lines when operating in GL-certified installations.
  • Ensure both redundant PROFIBUS RS485 lines are terminated with active 120 ohm bus termination resistors at both end nodes.
  • Route redundant RS485 communication cables through separate physical conduits to maintain physical path isolation against localized physical damage.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Top 5 Operational Advantages of HMIs in Modern Factory Automation

Top 5 Operational Advantages of HMIs in Modern Factory Automation

HMIs bridge the gap between operators and complex industrial control networks. Modern factory automation relies on HMIs to deliver real-time visualization, precise control, and data analytics alongside PLC and DCS infrastructure. This technical guide explores five core operational benefits of deploying HMIs in manufacturing.
Read more
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more