Product Description

The PM867 PM867K01 (3BSE076355R1) processor unit is a high-performance module within ABB’s AC800M controller family. It is designed for distributed control systems requiring redundancy, fast cycle execution, and robust communication. With extended firmware storage and optimized synchronization, the PM867 ensures reliable operation in mission-critical industrial environments.

Technical Specifications

  • Processor: MPC866 embedded CPU

  • Redundancy Switch-over Time: ≤ 10 ms

  • Application Handling:

    • 32 applications per controller

    • 64 programs per application

    • 128 diagrams per application

    • 32 tasks per controller

  • Cycle Times:

    • 32 configurable cycle times

    • Minimum cycle time down to 1 ms

  • Firmware Storage: 18 MB Flash PROM

  • Power Supply: 24 V DC (range 19.2–30 V DC)

  • Power Consumption: Typical 210 mA, maximum 360 mA

  • Power Dissipation: 5.1 W (maximum 8.6 W)

  • Redundant Power Input: Supported

  • Backup Battery: Lithium 3.6 V

  • Clock Synchronization: 1 ms accuracy via CNCP protocol

  • Event Handling:

    • Up to 3000 events per OPC client

    • Transmission speed: 36–86 events/sec, 113–143 data messages/sec

  • Communication Modules (CEX bus): Up to 12 modules, max 2.4 A supply current

  • I/O Clusters:

    • Non-redundant CPU: 1 electrical + 7 optical

    • Redundant CPU: 7 optical only

  • I/O Capacity: Max 96 modules (single PM867) or 84 modules (redundant PM867)

  • Modulebus Scan Rate: 0–100 ms depending on I/O configuration

  • Electrical Modulebus Supply Current:

    • 24 V: max 1.0 A

    • 5 V: max 1.5 A

  • Ethernet:

    • 2 channels, IEEE 802.3 standard

    • 10 Mbit/s, RJ-45 (8-pole female)

  • Control Network Protocols: MMS and IAC

  • Recommended Backbone: 100 Mbit/s switched Ethernet

  • Real-time Clock Stability: 100 ppm (~1 h/year)

  • RS-232 Interfaces:

    • 2 ports (general + service tool)

    • COM3 (non-redundant only): 75–19,200 baud, RJ-45, full RTS-CTS support

    • COM4 (non-redundant only): 9,600 baud, RJ-45, opto-isolated, no RTS-CTS support

Application Scenarios

  • Redundant CPU configurations for continuous process industries

  • OPC-based event-driven automation systems

  • Distributed control networks requiring precise synchronization

FAQ

Q: How much firmware storage does PM867 provide?  A: It offers 18 MB Flash PROM, larger than earlier models such as PM864.

Q: What is the redundancy switch-over time?  A: Maximum 10 ms, ensuring minimal disruption in redundant setups.

Q: How does PM867 differ from PM866?  A: PM867 provides expanded firmware storage and optimized redundancy handling compared to PM866.

Q: What communication protocols are supported?  A: MMS and IAC, with Ethernet IEEE 802.3 standard interfaces.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Spatial Computing in Industrial Automation: Elevating PLC and DCS Operations with AR and VR

Industry 4.0 integrates digital intelligence into field operations, transforming factory automation landscapes worldwide. Spatial technologies—specifically Augmented Reality (AR) and Virtual Reality (VR)—redefine how engineers interact with industrial control systems. By bridging computer-generated CAD models with real-time operational technology (OT) data, immersive displays enable intuitive monitoring, rapid diagnostics, and safer maintenance across complex processing facilities.

Read more
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more