Ürün Detayları
Configured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the Epro CON021/916-240 (CON021/916-240) converter paired with the PR6426/010-140 (PR6426/010-140) transducer provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CON021/916-240 + PR6426/010-140 |
| Brand | Epro (Emerson) |
| Origin | Germany |
| Weight | 0.92 kg (Combined) |
| Dimensions | Standard probe and LMgSi 0.5 F22 converter housing |
| Operating Temp | -30 deg C to +175 deg C |
| Power Consumption | Dependent on input voltage -21 VDC to -32 VDC |
| Measuring Range | 24.0 mm |
| Accuracy | +/- 1.5 % (Sensor sensitivity) |
| Output Signal | -4 VDC to -20 VDC or -2 VDC to -18 VDC |
Gap Voltage Validation (-10 VDC targets)
The system utilizes an oscillator circuit to drive the transducer probe. To ensure accurate linearization over the 24.0 mm extended measuring range, the system necessitates precise gap voltage validation. The converter centers its output characteristic around a nominal target of -10 VDC, which represents the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory during static commissioning; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.
Frequently Asked Questions
Q: Can the CON021/916-240 converter be used with shorter range sensors?
A: No. The converter is calibrated specifically for the 24.0 mm range of the PR6426 series. Using a different transducer will result in significant linearity errors exceeding the specified 3.5% threshold.
Q: Is the system capable of operating in pressurized environments?
A: The PR6426 sensor head is rated for pressure resistance up to 6,500 hPa (94 psi). Ensure the installation threads are sealed appropriately for the application pressure environment.
Field Installation Guidelines
- Mount the converter housing using four M5x20 screws onto a rigid, grounded surface to ensure structural integrity.
- Install the PR6426 probe into the mounting bracket, ensuring at least 200 mm shaft diameter clearance and adequate spacing from adjacent metallic structures to prevent cross-talk.
- Terminate the supply and output wiring using high-quality wire-end sleeves on the screw terminals, ensuring the cable conductor size does not exceed 1.5 mm².
- Verify the power supply polarity before applying voltage, as the unit requires -21 VDC to -32 VDC negative logic input.
- Ground the signal cable shield at the monitoring system (DCS/TSI) rack only to prevent ground-loop injection of 50/60 Hz electromagnetic noise.
Ek Bilgiler
- %100 Orijinal Parçalar: Tüm ürünler orijinal ve otantiktir, güvenilir endüstriyel performans sağlar.
- 30 Günlük İade Garantisi: Stokta bulunan herhangi bir ürünü, orijinal, açılmamış ambalajında 30 gün içinde tam para iadesi için iade edebilirsiniz (kargo ve ücretler hariç).
- 12 Aylık Garanti: Malzeme veya işçilik hatalarını kapsar; yanlış kullanım, normal aşınma veya yetkisiz değişiklikler hariçtir.
- Dünya Çapında Kargo: USPS, UPS, FedEx ve DHL ile gönderim yapıyoruz. Teslimat süreleri ülkeye göre değişir ve gümrük veya ithalat ücretlerine tabi olabilir.
- Destek & İletişim: Teknik ve garanti desteği her zaman mevcuttur. Bizimle buradan iletişime geçin: İletişim.
- Satın Alma Rehberi: Doğru uygulamayı sağlamak için sipariş vermeden önce ürün özelliklerini ve uyumluluğunu dikkatlice kontrol edin.