Product Overview

The Allen-Bradley 1788-EN2FFR acts as a high-availability gateway bridging redundant EtherNet/IP networks with Foundation Fieldbus H1 segments. This network linking device features dual RJ45 EtherNet/IP connectors and two sets of H1 media terminals, ensuring seamless and fault-tolerant data exchange between modern control systems and field instruments. It operates on a 24-32V DC power supply and features an open-style chassis designed for standard DIN rail mounting. We supply this item as a 100% Brand New, factory-sealed unit.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley (Rockwell Automation)
Product Series 1788 Linking Devices
Product Type Network Linking Module / Telecom Adaptor
Network Interfaces Redundant EtherNet/IP to Foundation Fieldbus
EtherNet/IP Ports 2 x RJ45 Connectors
Fieldbus Terminals 2 x Sets of H1 Media Terminals
Input Power 24 - 32V DC
Enclosure Type Open Style
Mounting Method DIN Rail Mounted
Weight 1.20 lbs (0.54 kg)

Engineering Advantages

Redundant Network Architecture
The 1788-EN2FFR is engineered for mission-critical process automation environments. By supporting redundant EtherNet/IP connections alongside dual H1 media terminals, it eliminates single points of failure. If a primary network cable or switch fails, the module seamlessly maintains communication, ensuring your control system retains continuous visibility and command over field devices without costly downtime.

Seamless Protocol Bridging
This linking device efficiently translates high-speed EtherNet/IP traffic into Foundation Fieldbus H1 signals. It allows modern Logix-based controllers to easily integrate with legacy or specialized field instruments (such as smart transmitters and valve positioners) that operate on the Foundation Fieldbus protocol, simplifying your overall system architecture and reducing the need for multiple disparate gateways.

Standardized Industrial Installation
Designed for rapid deployment in control cabinets, the open-style module mounts directly onto a standard DIN rail. The clear terminal blocks for both the 24-32V DC power and the H1 media simplify wiring and troubleshooting. Its compact 1.20 lbs footprint conserves valuable panel space while delivering robust telecommunications adaptability.

FAQs

Q: What network protocols does the 1788-EN2FFR connect?
A: This module acts as a bridge between a redundant EtherNet/IP network (using dual RJ45 ports) and Foundation Fieldbus H1 segments (using two sets of H1 media terminals), allowing seamless data exchange between the two protocols.

Q: What is the power requirement for this linking module?
A: The 1788-EN2FFR requires a DC power supply ranging from 24 to 32 volts. Ensure your control panel provides a stable voltage within this range for optimal operation.

Q: How does this module improve network reliability?
A: It features built-in redundancy for both the EtherNet/IP and Foundation Fieldbus connections. This dual-path capability ensures that communication remains active even if one network link experiences a physical fault or interruption.

Q: How is the 1788-EN2FFR mounted in a control panel?
A: The module features an open-style industrial design that snaps directly onto a standard DIN rail, allowing for quick installation, secure mounting, and easy removal for maintenance or replacement.

Informações Adicionais

  • Peças 100% Originais: Todos os produtos são originais e autênticos, garantindo desempenho industrial confiável.
  • Garantia de Reembolso de 30 Dias: Devolva qualquer item em estoque dentro de 30 dias na embalagem original e lacrada para reembolso total (excluindo frete e taxas).
  • Garantia de 12 Meses: Cobre defeitos de materiais ou fabricação; exclui uso indevido, desgaste normal ou modificações não autorizadas.
  • Envio para Todo o Mundo: Enviamos via USPS, UPS, FedEx e DHL. Os prazos de entrega variam conforme o país e podem estar sujeitos a taxas alfandegárias ou de importação.
  • Suporte e Contato: Assistência técnica e garantia disponível a qualquer momento. Contate-nos aqui: Contato.
  • Orientação para Compra: Verifique cuidadosamente as especificações e compatibilidade do produto antes de fazer o pedido para garantir a aplicação correta.




Produtos Visualizados Recentemente

Guia de Tecnologia e Compras

Informações Técnicas, Guias de Instalação e Dicas de Compra
Evolving SCADA System Architectures in Industrial Automation

Evolução das Arquiteturas de Sistemas SCADA na Automação Industrial

Um sistema robusto de Supervisão, Controle e Aquisição de Dados (SCADA) serve como o coração das operações industriais modernas. Compreender a arquitetura do sistema SCADA é vital para engenheiros que projetam sistemas de controle eficientes. Essas arquiteturas evoluíram de estruturas isoladas e monolíticas para ecossistemas altamente interconectados e em rede. Escolher o design certo requer equilibrar a visibilidade dos dados, o poder de processamento e os requisitos de escalabilidade a longo prazo.

Leia mais
Choosing the Right Controller: PLC vs. Motion Controller in Industrial Automation

Escolhendo o Controlador Certo: CLP vs. Controlador de Movimento na Automação Industrial

Selecionar a arquitetura de controle ideal é uma decisão fundamental na automação industrial. Os engenheiros frequentemente precisam escolher entre um Controlador Lógico Programável (CLP) e um Controlador de Movimento dedicado. Embora ambos os sistemas gerenciem máquinas, suas filosofias de design subjacentes diferem significativamente, impactando o desempenho, a escalabilidade e a integração do sistema.

Leia mais
Mastering PLC Power Supply Architectures and Operating Voltages

Dominando Arquiteturas de Fonte de Alimentação PLC e Tensões de Operação

Selecionar a tensão de operação correta é um passo crucial no projeto de sistemas confiáveis de automação industrial. Seja trabalhando com um PLC compacto ou um DCS de grande escala, a arquitetura de energia determina a longevidade do sistema. Neste guia, exploramos as faixas de tensão padrão e as estratégias de distribuição de energia necessárias para manter operações estáveis de automação de fábrica.

Leia mais