Skip to content

What are you looking for?


You may also like

Allen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis AdapterAllen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis AdapterAllen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis Adapter
Allen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis Adapter
Allen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis Adapter
Allen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis Adapter

Allen Bradley ControlLogix 1756-PSCA2 Redundant Power Supply Chassis Adapter


Only 10 left - Selling fast

PRODUCT SKU : 1756-PSCA2

PRODUCT TYPE : Power Supply Chassis Adapter

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley ControlLogix 1756-PSCA2 chassis adapter is engineered to support redundant power supply configurations, ensuring continuous operation in demanding industrial environments. By integrating this adapter, ControlLogix systems gain enhanced resilience against power supply failures, minimizing downtime and safeguarding critical processes.

Technical Specifications

  • Catalog Number / Model: 1756-PSCA2

  • Brand: Allen Bradley

  • Series: ControlLogix

  • Product Type: Redundant Power Supply Chassis Adapter

  • Lifecycle Status: Active

  • Compatibility: Designed exclusively for Allen Bradley ControlLogix redundant power supply modules

  • Installation: Tool-free mounting with seamless integration into existing chassis

  • Reliability: Industrial-grade construction for long-term durability and stable performance

  • Function: Provides redundant power interconnection between ControlLogix chassis power supplies

Application Scenarios

  • High-availability manufacturing lines requiring uninterrupted operation

  • Process industries such as chemical, pharmaceutical, and food production

  • Utility and energy systems where redundancy is critical for safety and compliance

FAQ

Q: What is the primary role of the 1756-PSCA2?  A: It enables redundant power supply connections, ensuring system uptime even if one supply fails.

Q: Can this adapter be used with non-ControlLogix systems?  A: No, it is specifically designed for ControlLogix redundant power supply modules.

Q: How does redundancy improve system reliability?  A: Redundancy ensures that if one power source fails, the backup supply maintains continuous operation.

Comparison with Similar Models

  • 1756-PSCA2: Standard chassis adapter for redundant power supply integration.

  • 1756-PSCA1: Compact version for smaller chassis setups.

  • 1756-PSCA3: Extended adapter option for larger system configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

In industrial automation, Programmable Logic Controllers (PLCs) are vital for control and monitoring. Over time, support and spare parts become limited, forcing engineers to decide between upgrading the existing PLC or migrating to a new system to maintain reliability and reduce downtime.

Read more
Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Commissioning a PLC control system is one of the most critical phases in any industrial automation project. It transforms design and programming into a fully functional, reliable system on site. For new PLC programmers, understanding each commissioning step ensures smooth integration, reduced downtime, and successful handover to the client.

Read more
Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

In modern industrial automation, reliable communication between remote I/O and PLCs is essential. The Schneider Electric CRA module enables efficient Ethernet-based remote I/O connectivity in PLC and DCS systems, improving scalability, diagnostics, and overall networked automation performance.



Read more