Skip to content

What are you looking for?


You may also like

Allen Bradley ControlLogix 1756-PBR2 Redundant Power Supply BundleAllen Bradley ControlLogix 1756-PBR2 Redundant Power Supply BundleAllen Bradley ControlLogix 1756-PBR2 Redundant Power Supply Bundle
Allen Bradley ControlLogix 1756-PBR2 Redundant Power Supply Bundle
Allen Bradley ControlLogix 1756-PBR2 Redundant Power Supply Bundle
Allen Bradley ControlLogix 1756-PBR2 Redundant Power Supply Bundle

Allen Bradley ControlLogix 1756-PBR2 Redundant Power Supply Bundle


Only 10 left - Selling fast

PRODUCT SKU : 1756-PBR2

PRODUCT TYPE : Power Supply Bundle

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley ControlLogix 1756-PBR2 is a redundant power supply bundle engineered to provide reliable DC input power for ControlLogix systems. Designed for high‑availability automation environments, this module ensures continuous operation by maintaining redundancy across critical power supply functions.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: ControlLogix

  • Catalog Number / Model: 1756-PBR2

  • Product Type: Redundant Power Supply Bundle

  • Weight: 13.69 lbs (6.21 kg)

  • Input Voltage Range: 19–32 VDC

  • Module Type: ControlLogix redundant power supply

  • Mounting: Compatible with ControlLogix chassis

  • Functionality: Provides backup power capability to reduce downtime risk

Application Scenarios

  • Continuous process industries requiring uninterrupted operation

  • Manufacturing systems with critical uptime requirements

  • Energy and utility sectors where redundant power is essential for compliance and safety

FAQ

Q: What is the purpose of the 1756-PBR2 bundle?  A: It delivers redundant DC input power to ControlLogix systems, ensuring uninterrupted operation.

Q: Can the 1756-PBR2 be used with non‑ControlLogix platforms?  A: No, it is specifically designed for ControlLogix chassis and modules.

Q: What input voltage does the module support?  A: The unit operates within a DC input range of 19–32 VDC.

Comparison with Similar Models

  • 1756-PBR2: Standard redundant DC power bundle for ControlLogix systems.

  • 1756-PB75: Single DC power supply option without redundancy.

  • 1756-PSCA2: Chassis adapter for redundant power supply integration.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more