Product Details

Overview

The Allen-Bradley 1747-L542 is a mid-range processor designed for the SLC 5/04 series, supporting moderate I/O and memory demands. It enables robust control and communication in legacy automation systems, compatible with both Data Highway Plus (DH+) and RS-232 protocols for programming and device interfacing. The module includes an integrated real-time clock, advanced instruction set, and battery-backed memory, offering reliable performance for a range of industrial applications.

Key Features

  • Mid-range processing for moderate I/O and memory requirements

  • DH+ networking for peer-to-peer communication with SLC, PLC, and PanelView devices

  • RS-232 port supporting DF1, ASCII, and Modbus RTU protocols

  • Advanced instruction set including math, PID, ASCII handling, and diagnostics

  • Integrated real-time clock for time-based operations and data logging

  • Supports battery backup for program and data retention

  • Chassis-mounted installation compatible with SLC 5/04 racks

  • Discontinued status with repair and replacement guidance from Rockwell Automation

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Line: SLC 5/04 Series

  • Part Number: 1747-L542

  • User Memory: 32K words

  • Communication Ports: DH+ (Data Highway Plus), RS-232 (DF1, ASCII, Modbus RTU)

  • Instruction Set: Advanced (math, PID, ASCII, diagnostics)

  • Real-Time Clock: Integrated

  • Battery Backup: Supported

  • Mounting Type: Chassis-based

  • Power Supply Requirement: Separate supply needed

  • Lifecycle Status: Discontinued, replacement recommended

  • Repair Options: Available via Rockwell Automation support

Application Scenarios

The 1747-L542 processor is suitable for:

  • Mid-range automation applications requiring reliable control and moderate memory

  • Integration into existing SLC 500 or SLC 5/04 infrastructure

  • Systems that require time-based logging or scheduling with the real-time clock

  • Networks using DH+ or RS-232 communication for device and operator interface

FAQs

Q: Can the 1747-L542 processor interface with modern devices?
A: It supports legacy DH+ and RS-232 protocols. For newer devices, converters or protocol adapters may be required.

Q: How much memory is available for user programs?
A: The module includes 32K words of user memory for program storage.

Q: Is battery backup supported?
A: Yes, battery-backed memory retains program and data when power is off.

Q: What replacement options exist for discontinued units?
A: Rockwell Automation provides engineering replacement guidance and repair services.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

In industrial automation, Programmable Logic Controllers (PLCs) are vital for control and monitoring. Over time, support and spare parts become limited, forcing engineers to decide between upgrading the existing PLC or migrating to a new system to maintain reliability and reduce downtime.

Read more
Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Commissioning a PLC control system is one of the most critical phases in any industrial automation project. It transforms design and programming into a fully functional, reliable system on site. For new PLC programmers, understanding each commissioning step ensures smooth integration, reduced downtime, and successful handover to the client.

Read more
Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

In modern industrial automation, reliable communication between remote I/O and PLCs is essential. The Schneider Electric CRA module enables efficient Ethernet-based remote I/O connectivity in PLC and DCS systems, improving scalability, diagnostics, and overall networked automation performance.



Read more