Description

The ABB CI820 (3BSE013200R1) is a Fieldbus Communication Interface connecting S800 I/O clusters to Advant Fieldbus 100 (AF 100) networks. Designed for high-availability systems, it supports redundant operation and ensures reliable, synchronized data exchange between local I/O modules and the master controller in mission-critical DCS applications.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Switzerland

  • Model Number: CI820

  • Order Number: 3BSE013200R1

  • Product Type: AF 100 Communication Interface

  • Weight: 0.38 kg

  • Protocol: Advant Fieldbus 100 (AF 100)

  • Redundancy: Supports Dual-FCI Redundant Configurations

  • Input Voltage: 24V DC (19.2 – 30V DC)

  • Mounting: DIN Rail (via TU840/TU841 Termination Units)

  • I/O Capacity: Up to 12 S800 I/O Modules per cluster

Features

  • Redundancy Management: Optimized for pairing in redundant setups to provide seamless failover protection for critical process communication.

  • Deterministic Communication: Utilizes the AF 100 bus to ensure high-speed, predictable data transmission between the I/O station and the central processor.

  • Local ModuleBus Control: Autonomously manages the scanning and health monitoring of connected S800 I/O modules, reducing the load on the main controller.

  • Intelligent Diagnostics: Features integrated LED status indicators for power, run, fault, and primary/backup station identification to simplify field maintenance.

  • Galvanic Isolation: Incorporates electrical isolation to protect internal control logic from external electrical noise and transients found in industrial environments.

  • Hot-Swap Capability: Supports the replacement of modules while the system is energized (when used with appropriate redundant baseplates), maximizing plant uptime.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more