PRODUCT SKU : 1769-OF4CI

PRODUCT TYPE : Isolated Analog Output Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1769-OF4CI is a high-precision isolated analog output module designed for ControlLogix and CompactLogix systems. It provides four differential, individually isolated outputs, enabling reliable analog signal control in industrial applications. This module is suitable for DIN rail or panel mounting and works seamlessly with Allen-Bradley 1769 series power supplies.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model / Catalog Number: 1769-OF4CI

  • Product Type: Isolated Analog Output Module

  • Outputs: 4 differential channels, individually isolated

  • Resolution: 16-bit unipolar

  • Maximum Conversion Rate (all channels): 110 ms

  • Rated Working Voltage: 30V AC / 30V DC

  • Isolation Voltage: 500V AC or 710V DC for 1 minute (IEC Class 2 reinforced insulation)

  • Maximum Heat Dissipation: 2.68 W

  • Module Mounting: DIN rail or panel mount

  • Compatible Power Supplies: 1769-PA2, 1769-PB2, 1769-PA4, 1769-PB4

  • Power Supply Distance Rating: Up to 8 modules away from the power supply

  • Slot Width: 1

  • Dimensions (L x W x H): 11.8 × 3.5 × 8.7 cm

  • Shipping Weight: 2.5 kg

Key Features

  • Individually isolated analog outputs for high reliability

  • 16-bit resolution ensures precise signal control

  • Compact design for easy DIN rail or panel installation

  • Compatible with multiple 1769 series power supplies for flexible deployment

  • Safe reinforced insulation to separate output groups from backplane power

Applications

  • Precise analog control in process and discrete automation

  • Integration with ControlLogix and CompactLogix systems

  • Signal output in instrumentation, monitoring, and control systems

FAQs

Q1: How many outputs does the 1769-OF4CI module support?
It supports four differential, individually isolated analog outputs.

Q2: Can this module be mounted on a panel?
Yes, the 1769-OF4CI supports both DIN rail and panel mounting.

Q3: What is the isolation voltage for this module?
It provides 500V AC or 710V DC isolation for 1 minute, meeting IEC Class 2 reinforced insulation standards.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

Upgrading vs. Migrating PLC Systems: Choosing the Right Strategy for Industrial Automation

In industrial automation, Programmable Logic Controllers (PLCs) are vital for control and monitoring. Over time, support and spare parts become limited, forcing engineers to decide between upgrading the existing PLC or migrating to a new system to maintain reliability and reduce downtime.

Read more
Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Site Commissioning Steps for PLC Programmers: A Complete Industrial Automation Guide

Commissioning a PLC control system is one of the most critical phases in any industrial automation project. It transforms design and programming into a fully functional, reliable system on site. For new PLC programmers, understanding each commissioning step ensures smooth integration, reduced downtime, and successful handover to the client.

Read more
Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

Understanding the CRA Module in Schneider PLC Systems: Remote I/O Communication and Network Reliability

In modern industrial automation, reliable communication between remote I/O and PLCs is essential. The Schneider Electric CRA module enables efficient Ethernet-based remote I/O connectivity in PLC and DCS systems, improving scalability, diagnostics, and overall networked automation performance.



Read more