Skip to content

What are you looking for?


You may also like

1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex
1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex
1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex
1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex

1715-TADIB16D | Allen Bradley Termination Assembly 16-Channel DI Duplex


Only 10 left - Selling fast

PRODUCT SKU : 1715-TADIB16D

PRODUCT TYPE : Termination Assembly

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1715-TADIB16D Termination Assembly is designed for 16-channel digital input duplex applications, providing reliable signal termination, fuse protection, and isolation features for distributed I/O systems. It is engineered to deliver consistent performance in industrial automation environments where redundancy and accuracy are essential.

Technical Specifications

  • Manufacturer: Allen-Bradley

  • Product Number: 1715-TADIB16D

  • Product Type: Termination Assembly, 16-Channel DI Duplex

  • Fuse Rating: 50 mA per channel

  • Screw Torque: 0.5 N·m (0.37 lb·ft)

  • Screwdriver Width: Flathead 0.4 × 2.0 mm (0.0156 × 0.0781 in.)

  • Backplane Current: 6.5 mA per channel at 0–32 VDC

  • Slew Rate (Max): 3600 V/s

  • Translation Rate (Max): 1 / (Application scan time + 10 ms) Hz

  • System Power Dissipation: 4.0 W maximum

  • Field Loop Power Dissipation: 0.2 W per loop maximum

  • Isolation Voltage: 50 V continuous, basic insulation type (I/O ports to backplane); no isolation between individual I/O ports with 1715-TASIB16D; 50 V isolation between individual ports with 1715-TADIB16D; type tested at 500 V AC for 60 seconds

  • Dimensions (W × H): 8.4 cm × 13.2 cm

  • Weight: 0.36 kg

Application Scenarios

  • Digital Input Monitoring: Provides reliable termination for duplex digital input signals

  • Distributed I/O Systems: Ensures redundancy and stable performance in complex automation networks

  • Industrial Environments: Suitable for manufacturing, process control, and safety-critical applications requiring channel isolation

FAQ

  • Q: What isolation does this assembly provide?  A: The 1715-TADIB16D offers 50 V isolation between individual I/O ports, unlike the 1715-TASIB16D which does not provide port-to-port isolation.

  • Q: What is the maximum system power dissipation?  A: The system power dissipation is 4.0 W maximum, with 0.2 W per field loop.

  • Q: What type of fuse protection is included?  A: Each channel is protected with a 50 mA fuse, ensuring fault isolation and reliability.

  • Q: How does this model compare to the 1715-TADOB8DE?  A: The 1715-TADIB16D is designed for digital input duplex applications with isolation features, while the 1715-TADOB8DE is intended for digital output duplex configurations.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more