Skip to content

What are you looking for?


You may also like

ARM55D-000 CENTUM VP Relay Output Board | YokogawaARM55D-000 CENTUM VP Relay Output Board | YokogawaARM55D-000 CENTUM VP Relay Output Board | Yokogawa
ARM55D-000 CENTUM VP Relay Output Board | Yokogawa
ARM55D-000 CENTUM VP Relay Output Board | Yokogawa
ARM55D-000 CENTUM VP Relay Output Board | Yokogawa

ARM55D-000 CENTUM VP Relay Output Board | Yokogawa


Only 10 left - Selling fast

PRODUCT SKU : ARM55D-000

PRODUCT TYPE : Relay Output Board

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ARM55D-000 serves as a robust 32-point relay interface for high-integrity control systems. This module provides mechanical dry contact outputs using "a" contact (Normally Open) logic, making it essential for switching field devices in both single and dual-redundant configurations. We supply this unit as 100% Brand New and Original, ensuring optimal contact conductivity and mechanical longevity for your Distributed Control System (DCS) infrastructure.

Part Number Breakdown

Code Specification Detail
ARM55D Model 32-Point Dry Contact Outputs (M4 Terminals)
-0 Fixed Code Always 0
0 Mounting 19-inch Rack Mountable
0 Type Basic type hardware

Technical Specifications

Feature Details
Contact Type Mechanical Relay Dry Contact ("a" contact / NO)
Number of Points 32-point
Redundancy Support Supports Single or Dual-redundant setups
Field Terminals M4 screws
Insulation Resistance At least 10 MΩ (measured at 500 V DC)
Mounting Standard 19-inch Rack Mount
Dimensions 18.4 cm x 48.2 cm x 13.2 cm
Weight 2.2 kg

Engineering Advantages

  • High-Torque Field Termination: The ARM55D-000 utilizes M4 screw terminals for field device connections. This larger screw size allows for higher tightening torque compared to standard M3 terminals, preventing loose connections in environments subject to industrial vibration.

  • Redundancy Ready: This board supports dual-redundant configurations, allowing the control system to maintain operation even if a primary signal path encounters an issue. This architecture eliminates single points of failure in critical interlock or shutdown loops.

  • Standardized Rack Integration: The 19-inch rack-mountable design facilitates seamless integration into standard industrial cabinets. The fixed dimensions ensure that the board aligns perfectly with other FA-M3 or CENTUM series hardware, optimizing cable routing and airflow.

  • Superior Galvanic Isolation: With an insulation resistance of at least 10 MΩ at 500 V DC, the board provides a high-integrity barrier between the control logic and the field environment. This prevents ground loops and protects sensitive electronics from high-voltage transients present on the field side.

FAQs

  • What is the difference between the ARM55D and ARM55C models?

    The ARM55D model specifically features larger M4 terminal screws for field connections, whereas other models may use M3.5 or different connector types. The ARM55D is optimized for heavy-gauge field wiring and high-vibration applications.

  • Does this board support Normally Closed (NC) configurations?

    No. The ARM55D-000 utilizes "a" contact logic, which refers to Normally Open (NO) mechanical relays. If your application requires NC logic, you must handle the inversion through the DCS software or use an external interposing relay.

  • What are the mounting requirements for this unit?

    The board requires a standard 19-inch rack space. Ensure you provide sufficient clearance for the 18.4 cm depth to allow for wire bend radiuses and proper ventilation within the cabinet.

  • Is the 10 MΩ insulation resistance sufficient for high-voltage environments?

    Yes, the 10 MΩ rating at 500 V DC exceeds the requirements for standard industrial digital output modules. It ensures that the board safely isolates low-voltage control signals from 24VDC or 110VAC field circuits.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more