Configured for rotational speed monitoring in industrial governor platforms, the Woodward 5464-414 (5464-414 Digital Micro Processor Speed Sensor) provides direct physical/electrical execution of frequency-to-digital signal conversion.

Hardware Specifications

Parameter Specification
Model 5464-414
Brand Woodward
Origin USA
Weight 0.96 kg
Dimensions 2.6 x 24.8 x 26.2 cm
Input Types Pulse train, analog, digital
Output Types Digital and analog signals

Actuator Loop Feedback Response

The 5464-414 utilizes digital signal processing to convert mechanical rotation into actionable data for governing control loops. By providing precise frequency-based feedback, the module enables the connected controller to maintain a stable actuator loop feedback response. The conversion latency of the internal microprocessor is optimized to minimize phase shift, ensuring that the governor can respond effectively to transient load fluctuations without introducing oscillatory behavior into the fuel control system.

Frequently Asked Questions

Q: Does the 5464-414 require specific shielding for input signal cables?

A: Yes, due to the nature of pulse train and low-level analog speed inputs, use shielded twisted-pair cabling. The shield must be terminated at the control system ground point to minimize induced electromagnetic noise.

Q: Is this module field-configurable for different input signal ranges?

A: The module supports various input types, including pulse trains and analog signals. Configuration should be performed via the associated Woodward controller's software interface to match the sensor's pulse-per-revolution (PPR) count and signal voltage levels.

Field Installation Guidelines

  1. Mounting: Secure the module within a vibration-dampened cabinet. Ensure the 2.6 x 24.8 x 26.2 cm chassis is oriented to facilitate airflow around the electronics.
  2. Wiring: Separate signal lines from high-current AC output or drive lines to prevent induced electrical noise from corrupting the speed data.
  3. Grounding: Establish a low-impedance ground connection to the module chassis. Verify the integrity of the connection to the common system reference point.
  4. Validation: During commissioning, verify the input frequency against a secondary tachometer reading to confirm the accuracy of the digital pulse conversion before enabling closed-loop governor control.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more