Product Details

The Honeywell TL-Q5MC1, also cataloged as the TL-Q5MC1 Inductive Proximity Sensors, operates as a dedicated hardware component for non-contact metallic target detection within automated industrial sensing loops.

Hardware Specifications

Parameter Specification
Model TL-Q5MC1
Brand Honeywell
Origin USA / Global Manufacturing
Operating Temp -25 to +70 deg C
Power Consumption Current consumption <= 10 mA at 24 VDC
Supply Voltage Range 10-30 VDC (Rated: 12-24 VDC, ripple < 10%)
Output Type NPN open collector
Output Configuration Normally Open (NO)
Max Switching Current 50 mA
Max Load Voltage 30 VDC
Residual Voltage <= 1 V at 50 mA (2 m cable)
Response Frequency 500 Hz
Response Time <= 2 ms
Protection Circuits Reverse polarity protection, surge suppression

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

When integrated alongside analog field instrumentation, the TL-Q5MC1 digital switching signals pass to DCS discrete input channels without inducing switching noise into adjacent 4-20 mA HART loop protocol lines. Internal surge suppression network components absorb transient voltage spikes during high-frequency actuation up to 500 Hz.

Maintaining proper channel-to-channel isolation on the receiving I/O termination block ensures that NPN open collector switching currents up to 50 mA do not alter analog loop current references or disrupt low-level digital telecommunication layers across neighboring terminal blocks.

Frequently Asked Questions

Q: What is the maximum switching frequency supported by the TL-Q5MC1 proximity sensor?

A: The sensor operates at a maximum response frequency of 500 Hz with a maximum response time of 2 ms.

Q: Does the TL-Q5MC1 include internal protection against reversed supply wiring?

A: Yes, the sensor includes built-in reverse polarity protection and surge suppression circuitry to prevent internal component damage.

Q: What electrical load limitations apply to the NPN output stage?

A: The NPN open collector output handles a maximum switching current of 50 mA with a maximum load voltage of 30 VDC.

Field Installation Guidelines

  • Verify input voltage supply limits are within 10-30 VDC with ripple below 10% before applying system power.
  • Ensure target metal mass meets standard sensing face alignment requirements to guarantee full 500 Hz switching capability.
  • Connect sensor cable shielding to the designated earth ground terminal in the junction box to prevent EMI coupling.
  • Maintain physical isolation between sensor signal cabling and high-power AC motor or drive wiring in cabinet channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more