PRODUCT SKU : PR9376/010-001

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for rotational velocity acquisition in industrial machinery, the Epro PR9376/010-001 (PR9376/010-001) Hall-Effect Speed and Proximity Sensor provides direct electrical execution of non-contact pulse generation from rotating ferromagnetic targets.

Hardware Specifications

Parameter Specification
Model PR9376/010-001
Brand Epro
Origin Germany
Operating Temp -25 deg C to +100 deg C
Power Consumption <= 25 mA (10-30 VDC)
Output Digital pulse (High >10 V / Low <1 V)
Frequency Capability Up to 12 kHz
Air Gap 1.0 mm to 1.5 mm

Mechanical Monitoring and TSI Characteristics

The PR9376/010-001 utilizes Hall-effect magnetic detection to monitor shaft speed by tracking the passage of gear teeth or keyways. To ensure signal fidelity, maintain the specified air gap strictly; deviation from the 1.0 mm or 1.5 mm tolerance will degrade pulse amplitude and timing accuracy. In multi-sensor TSI arrays, ensure proper cable routing to prevent cross-talk between high-speed signal channels, as external electromagnetic interference can distort transition characteristics. The sensor output provides 1 AC cycle per gear tooth pass, requiring a clean ferromagnetic target surface to avoid pulse dropout or erratic switching.

Frequently Asked Questions

Q: Is the 12 kHz frequency capability sufficient for all turbine applications?

A: The 12 kHz limit covers most standard industrial applications. For high-speed rotors with high-tooth-count gears, ensure the calculated pulse frequency does not exceed the sensor's bandwidth to prevent pulse skipping or output saturation.

Q: How should the sensor be oriented relative to the gear teeth?

A: The sensor must be mounted perpendicular to the target surface. The active tip must face the ferromagnetic material directly to achieve the magnetic flux variation required to trigger the Hall-effect switch logic.

Field Installation Guidelines

  1. Ensure the mounting bracket is rigid to avoid vibration-induced changes to the air gap, which can cause intermittent signal loss.
  2. Terminate the cable at the monitoring system input; ensure the shield is connected at the control cabinet side to mitigate electromagnetic interference.
  3. Check the target material properties; ensure it is a soft magnetic steel to maintain optimal flux density for the Hall-effect element.
  4. Verify the power supply voltage is within the 10-30 VDC range.
  5. Perform a commissioning test by manually rotating the shaft at low speed to confirm square wave pulse generation before applying full operational velocity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more