PRODUCT SKU : PR9376/010-001

PRODUCT TYPE : Proximity Sensors

PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for rotational velocity acquisition in industrial machinery, the Epro PR9376/010-001 (PR9376/010-001) Hall-Effect Speed and Proximity Sensor provides direct electrical execution of non-contact pulse generation from rotating ferromagnetic targets.

Hardware Specifications

Parameter Specification
Model PR9376/010-001
Brand Epro
Origin Germany
Operating Temp -25 deg C to +100 deg C
Power Consumption <= 25 mA (10-30 VDC)
Output Digital pulse (High >10 V / Low <1 V)
Frequency Capability Up to 12 kHz
Air Gap 1.0 mm to 1.5 mm

Mechanical Monitoring and TSI Characteristics

The PR9376/010-001 utilizes Hall-effect magnetic detection to monitor shaft speed by tracking the passage of gear teeth or keyways. To ensure signal fidelity, maintain the specified air gap strictly; deviation from the 1.0 mm or 1.5 mm tolerance will degrade pulse amplitude and timing accuracy. In multi-sensor TSI arrays, ensure proper cable routing to prevent cross-talk between high-speed signal channels, as external electromagnetic interference can distort transition characteristics. The sensor output provides 1 AC cycle per gear tooth pass, requiring a clean ferromagnetic target surface to avoid pulse dropout or erratic switching.

Frequently Asked Questions

Q: Is the 12 kHz frequency capability sufficient for all turbine applications?

A: The 12 kHz limit covers most standard industrial applications. For high-speed rotors with high-tooth-count gears, ensure the calculated pulse frequency does not exceed the sensor's bandwidth to prevent pulse skipping or output saturation.

Q: How should the sensor be oriented relative to the gear teeth?

A: The sensor must be mounted perpendicular to the target surface. The active tip must face the ferromagnetic material directly to achieve the magnetic flux variation required to trigger the Hall-effect switch logic.

Field Installation Guidelines

  1. Ensure the mounting bracket is rigid to avoid vibration-induced changes to the air gap, which can cause intermittent signal loss.
  2. Terminate the cable at the monitoring system input; ensure the shield is connected at the control cabinet side to mitigate electromagnetic interference.
  3. Check the target material properties; ensure it is a soft magnetic steel to maintain optimal flux density for the Hall-effect element.
  4. Verify the power supply voltage is within the 10-30 VDC range.
  5. Perform a commissioning test by manually rotating the shaft at low speed to confirm square wave pulse generation before applying full operational velocity.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more