The Yokogawa CP332D, also cataloged as the CP332D Power Supply Module, operates as a dedicated hardware component for direct AC to DC conversion and regulated DC voltage distribution within Yokogawa industrial control platforms.

Hardware Specifications

Parameter Specification
Model CP332D
Brand Yokogawa
Origin Japan
Weight 2.5 kg
Dimensions 220 mm x 110 mm x 45 mm
Operating Temp -10 to 50 deg C
Power Consumption 2 A max at 100 VAC to 240 VAC
Output Voltage Range 0 V to 32 V
Output Current Range 0 A to 3 A
Output Ripple and Noise < 100 mVp-p
Line Regulation +/-0.05%
Load Regulation +/-0.05%
Input Voltage 100 VAC to 240 VAC
Storage Temperature -20 to 60 deg C
Remote Interface RS-232C

4-20 mA HART Loop Protocol and Channel-to-Channel Isolation

The CP332D integrates internal line-side galvanic isolation to insulate low-voltage DC logic and field buses from AC power mains transients. Within Yokogawa process automation sub-racks hosting 4-20 mA HART loop protocol transmitters and I/O cards, the module maintains tight line and load regulation (+/-0.05%) while output ripple and noise are suppressed under 100 mVp-p. This regulation performance mitigates common-mode electrical interference across process measurement channels.

Frequently Asked Questions

Q: How is the output voltage and current controlled remotely on the CP332D?

A: Parameter adjustment and real-time status monitoring are executed via the integrated RS-232C serial communication interface.

Q: What protective features are built into the CP332D output circuit?

A: The module incorporates internal overvoltage, overcurrent, and short-circuit protection circuits to halt output generation during electrical faults.

Field Installation Guidelines

  • ESD Protection: Wear a grounded anti-static wrist strap during module installation and terminal wiring to prevent electrostatic discharge damage.
  • AC Input Line Isolation: Ensure main AC supply lines are de-energized and locked out before wiring conductors to input power terminals.
  • Protective Earthing: Connect the designated protective earth (PE) ground terminal to the main enclosure grounding bus via a short, low-impedance copper lead.
  • Wiring Separation: Route AC power input cables in separate conduits away from sensitive low-voltage DC output lines and signal buses to avoid inductive coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more