PRODUCT SKU : FC-PSU-UNI2450U V1.0

PRODUCT TYPE : Power Supply Units

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell FC-PSU-UNI2450U V1.0, also cataloged as the FC-PSU-UNI2450U Power Supply Module, operates as a dedicated hardware component for AC-to-DC power conversion and high-current voltage stabilization within Honeywell Safety Manager and DCS platforms.

Hardware Specifications

Parameter Specification
Model FC-PSU-UNI2450U V1.0
Brand Honeywell
Origin USA
Weight 4.41 kg
Dimensions Standard system rack power module dimensions
Operating Temp -20 to +70 deg C (Full load to +50 deg C; half load to +70 deg C)
Power Consumption Internal conversion loss dependent on load efficiency
Input Voltage Range 110-240 VAC
Input Current 14-6 A
Input Frequency 50-60 Hz
Output Voltage 25 VDC or 28 VDC
Output Current 48 A at 25 VDC / 43 A at 28 VDC
Part Number 136-012000G51
Approval Certification E168320 (Industrial Control Equipment)

Process Control & DCS Power Infrastructure Characteristics

The FC-PSU-UNI2450U V1.0 incorporates channel-to-channel isolation and integrated surge suppression to maintain continuous power stability across DCS controllers and field instrumentation loops. Designed to handle severe main line variations, the unit supports both 25 VDC and 28 VDC field wiring drops using a 4-20 mA HART loop protocol environment without introducing ripple noise into analog input modules. Onboard power regulation circuits isolate internal logic solvers from field-side short circuits and ground loop faults.

Frequently Asked Questions

Q: What is the thermal derating requirement for the FC-PSU-UNI2450U V1.0 when cabinet temperatures exceed 50 deg C?

A: The power supply delivers its full rated output current (48 A at 25 VDC / 43 A at 28 VDC) up to a maximum surrounding air temperature of 50 deg C. Between 50 deg C and 70 deg C, the total continuous output current must be derated linearly down to 50% capacity.

Q: How is the output voltage specified between 25 VDC and 28 VDC executed on this hardware?

A: The module is configured at the factory/hardware selection pin level (Vb1200-1-r interface) to supply either 25 VDC at 48 A or 28 VDC at 43 A to compensate for IR voltage drops across long field cable runs to FTAs.

Field Installation Guidelines

  1. Physical Mounting: Install the unit vertically into the designated enclosure chassis slot. Secure all retaining hardware to guarantee frame grounding and mechanical stability against industrial vibration.
  2. AC Input Connections: Wire the primary AC source (110-240 VAC, 50-60 Hz) to the input terminals using correctly sized conductors rated for at least 14 A line current. Ensure phase, neutral, and protective earth conductors are terminated properly.
  3. Shielding & Grounding: Connect the system protective earth lug directly to the master enclosure copper ground bus using a low-impedance ground strap to reject common-mode electrical noise.
  4. Thermal Ventilation: Maintain minimum 50 mm clearance above and below the module ventilation openings to permit passive heat dissipation and maintain thermal limits inside the cabinet.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more
Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Voice-Activated Industrial Automation: Integrating Speech Control into PLC and DCS Architectures

Industrial automation integrates speech recognition, IIoT protocols, and NLP with PLCs and DCS to streamline operations. By leveraging advanced edge computing, engineers enable real-time, hands-free control—allowing personnel to manage smart factory processes safely away from hazardous equipment.

Read more
Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Modern Industrial Automation: Transforming Safety and Efficiency in Mining Operations

Industrial automation has evolved from a simple manufacturing tool into the operational backbone of high-risk sectors. Modern mining operations increasingly rely on advanced control systems, programmable logic controllers (PLCs), distributed control systems (DCS), and artificial intelligence to address deep-underground hazards. By replacing manual labor in high-risk zones, factory automation technologies protect personnel while significantly boosting operational throughput.

Read more