Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply BundleAllen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply BundleAllen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply Bundle
Allen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply Bundle
Allen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply Bundle
Allen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply Bundle

Allen-Bradley 1756-PAR2 ControlLogix AC Redundant Power Supply Bundle


Only 10 left - Selling fast

PRODUCT SKU : 1756-PAR2

PRODUCT TYPE : AC Redundant Power Supply Bundle

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-PAR2 is a ControlLogix AC redundant power supply bundle designed for high-reliability applications. It delivers multiple DC output voltages and currents to support a full ControlLogix system, with robust performance across a wide AC input range.

Technical Specifications

  • Manufacturer Allen-Bradley (Rockwell Automation)

  • Series ControlLogix

  • Model / Part Number 1756-PAR2

  • Product Type AC Redundant Power Supply Bundle

  • Input Voltage 85–265 V AC

  • Frequency Range 47–63 Hz

  • Output Voltages & Currents 5 V DC @ 13 A, 3.3 V DC @ 4 A, 1.2 V DC @ 1.5 A, 24 V DC @ 2.8 A

  • Power Rating 75 W

  • Mounting Panel mount

  • Operating Temperature 0–60 °C (32–140 °F)

  • Redundancy Supports AC redundant configuration

  • Standards GOST, KC

  • Weight 6.8 kg

Key Features

  • Delivers multiple DC outputs for comprehensive ControlLogix system support

  • AC redundant capability ensures uninterrupted operation during power failures

  • Wide input voltage range supports international AC power systems

  • Panel-mountable with standard industrial installation options

  • Compliant with GOST and KC standards for global deployment

Application Scenarios

The 1756-PAR2 is suitable for:

  • Redundant power supply in high-availability ControlLogix systems

  • Critical process control and industrial automation applications

  • OEM machinery requiring reliable multi-voltage DC distribution

Similar Models Comparison

  • 1756-PAR2 – AC redundant bundle with 5V, 3.3V, 1.2V, 24V outputs

  • 1756-PB75R – Redundant AC/DC power supply with higher current ratings

  • 1756-PA75R – Standard AC/DC redundant module, lower power bundle

FAQs

Q: What is the AC input voltage range?
A: The module accepts 85–265 V AC at 47–63 Hz.

Q: What DC outputs are available?
A: Provides 5 V DC @ 13 A, 3.3 V DC @ 4 A, 1.2 V DC @ 1.5 A, 24 V DC @ 2.8 A.

Q: Can it be used in redundant configuration?
A: Yes, designed for AC redundant operation with compatible ControlLogix modules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more