Woodward 5441-693 Discrete I/O ModuleWoodward 5441-693 Discrete I/O ModuleWoodward 5441-693 Discrete I/O Module
Woodward 5441-693 Discrete I/O Module
Woodward 5441-693 Discrete I/O Module
Woodward 5441-693 Discrete I/O Module

Woodward 5441-693 Discrete I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 5441-693

PRODUCT TYPE : Discrete I/O Modules

PRODUCT VENDOR : Woodward


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal management in control platforms, the Woodward 5441-693 (5441-693 Discrete I/O Module) provides direct physical/electrical execution of 24 optically isolated input channels and 13 relay-based switching circuits.

Hardware Specifications

Parameter Specification
Model 5441-693
Brand Woodward
Origin USA
Input Channels 24 (Optically isolated)
Relay Circuits 13
Update Time 5 ms
Time Stamping 1 ms resolution
Contact Supply 24 VDC (400 mA max)

V/Hz and Field-Oriented Vector Control

The 5441-693 supports the execution of V/Hz and field-oriented vector control by providing rapid state monitoring and deterministic switching. The 24 optically isolated inputs enable the controller to ingest real-time feedback regarding system status, while the 13 relay circuits facilitate the final control elements necessary for actuator loop feedback response. The 1 ms time-stamping resolution ensures that discrete state transitions are accurately captured for diagnostic logging, allowing for precise correlation between control commands and system responses in high-speed automation sequences.

Frequently Asked Questions

Q: Can the 24 VDC contact supply power external field devices directly?

A: The module provides an isolated 24 VDC contact supply with a maximum current capacity of 400 mA. Ensure that the total current draw of all connected field sensors does not exceed this limit to avoid voltage sag or module protection triggering.

Q: Are the 13 relay circuits independently addressable?

A: Yes, the 13 relay circuits are designed for independent switching and control functionality. Verify the PLC output mapping configuration to ensure correct logical assignment for each relay circuit during commissioning.

Field Installation Guidelines

  1. Mounting: Install the module within a clean, dry control cabinet. Ensure the mounting surface provides sufficient heat dissipation area to maintain internal component longevity.
  2. Wiring: Use shielded cabling for all discrete inputs to prevent electromagnetic interference. Keep high-power relay output wiring physically separated from low-voltage input signal lines to mitigate crosstalk.
  3. Isolation Requirements: Although the inputs are optically isolated, ensure all common points are correctly referenced to the power source to maintain the integrity of the isolation barrier.
  4. Relay Loading: Observe the relay contact ratings for inductive loads. Use external suppression (e.g., flyback diodes for DC, RC snubbers for AC) when switching high-inductance coils to prevent contact pitting and extend relay service life.
  5. Validation: After installation, verify the status of all 24 inputs using the PLC diagnostic interface. Test each of the 13 relay circuits individually to confirm proper actuation before enabling system-wide control.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

Executing a PLC System Site Acceptance Test (SAT): The Definitive Engineering Guide

The transition of a Programmable Logic Controller (PLC) cabinet from a controlled factory floor to a volatile plant environment represents a critical milestone in factory automation. While a Factory Acceptance Test (FAT) validates standalone hardware compliance under ideal conditions, it cannot replicate real-world process dynamics. Therefore, deploying an industrial automation system requires a rigorous Site Acceptance Test (SAT) to verify total loop integrity, field wiring wiring metrics, and process control parameters before final customer handover.

Read more
Advanced Integration: Master Protocol for VFD Commissioning and Testing

Advanced Integration: Master Protocol for VFD Commissioning and Testing

Deploying variable frequency drives (VFDs) requires precise execution during the initial commissioning phase. Junior automation engineers often find the first power-up sequence intimidating. However, following a rigorous engineering framework ensures equipment safety and system reliability. Proper startup procedures protect both the drive electronics and the connected motor.

Read more
Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Optimizing Factory Automation: The Definitive Guide to VFD Preventive Maintenance

Variable Frequency Drives (VFDs) serve as critical assets in modern industrial automation. These power electronic devices regulate electric motors by adjusting the supplied frequency and voltage. Consequently, industries utilize VFDs to reduce energy consumption and optimize process control. Major manufacturers like Siemens, ABB, and Yaskawa design highly efficient drives. However, sustained efficiency requires a rigorous preventive maintenance program.

Read more