Skip to content

What are you looking for?


You may also like

T8850 | ICS TRIPLEX | Expander Interface ModuleT8850 | ICS TRIPLEX | Expander Interface ModuleT8850 | ICS TRIPLEX | Expander Interface Module
T8850 | ICS TRIPLEX | Expander Interface Module
T8850 | ICS TRIPLEX | Expander Interface Module
T8850 | ICS TRIPLEX | Expander Interface Module

T8850 | ICS TRIPLEX | Expander Interface Module


Only 10 left - Selling fast

PRODUCT SKU : T8850

PRODUCT TYPE : Field Termination Assemblies

PRODUCT VENDOR : ICS Triplex


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for signal termination within the Trusted TMR system, the ICS TRIPLEX T8850 (T8850 Field Termination Assembly) provides direct physical and electrical execution. The unit functions as the primary interface between field-mounted digital instrumentation and the T8403 digital input modules, facilitating signal routing and localized power distribution for up to 40 individual channels.

Hardware Specifications

Parameter Specification
Model T8850
Brand ICS TRIPLEX
Origin United States (US)
Weight 0.8 kg
Dimensions 16 cm x 16 cm x 12 cm
Operating Temp Standard Industrial
Power Consumption Configuration Dependent
Input Channels 40 Channels
Operating Voltage 24 VDC

SIS Fail-Safe State Execution

The T8850 assembly incorporates per-channel fusing to ensure localized fault isolation, maintaining the integrity of the broader safety instrumented system (SIS). By providing galvanic isolation between field-side signals and the TMR input modules, the FTA prevents the propagation of electrical transients or short-circuit events to the primary processor. In the event of a field-side fault, the assembly ensures that the failed channel does not influence the voltage levels or signal state of adjacent channels, adhering to strict fail-safe state execution protocols required for safety-critical applications.

Frequently Asked Questions

Q: Does the T8850 support hot-swapping of connected digital input modules?

A: Yes, the T8850 utilizes a SmartSlot connection design that enables the hot replacement of associated T8403 input modules. This allows for module maintenance without requiring the disconnection of field wiring or a system-wide shutdown.

Q: How is field power integrity monitored on the T8850?

A: Each channel utilizes integrated LED indicators located on the assembly to provide visual confirmation of field power supply status. A loss of local power or a blown fuse will be indicated by the extinguished LED corresponding to the specific input channel.

Field Installation Guidelines

  1. Secure the T8850 assembly to a standard industrial DIN rail, ensuring the mounting clips are fully engaged for physical stability.
  2. Terminate 2-wire field devices directly to the designated terminals, observing proper polarity for the 24 VDC signal loop.
  3. Verify that all field wiring is properly shielded and routed away from high-voltage AC lines to mitigate electromagnetic interference.
  4. Check that the SmartSlot connection is free of debris and debris-free before inserting the T8403 digital input module.
  5. Ensure the grounding lug is connected to the system reference ground to facilitate surge voltage protection and signal reference stability.
  6. Confirm the integrity of the fuse per channel after initial power-on to ensure the circuit is active and protected.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
Mastering Modern Industrial Joystick Controls in Heavy Automation

Mastering Modern Industrial Joystick Controls in Heavy Automation

Industrial joysticks play a pivotal role in human-machine interaction across heavy material handling and mobile hydraulics. These tactile controllers translate complex operator movements into precise electrical signals for PLCs, motion controllers, and DCS networks. Consequently, selecting and installing the right joystick architecture ensures operator safety, reduces fatigue, and optimizes equipment performance.

Read more