PRODUCT SKU : IS200STCIH6A

PRODUCT TYPE : Contact Input Terminal Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for discrete signal acquisition in Mark VIe distributed control platforms, the GE IS200STCIH6A (IS200STCIH6A Contact Input Terminal Board) provides direct physical/electrical execution of field contact monitoring.

Hardware Specifications

Parameter Specification
Model IS200STCIH6A
Brand General Electric
Origin USA
Input Capacity 24 contact inputs
Input Voltage Range 24 V DC, 48 V DC, 125 V DC

Industrial Control and I/O Density Scaling

The IS200STCIH6A functions as a termination interface for field-level discrete inputs, supporting nominal voltages of 24, 48, and 125 V DC. The board incorporates integrated noise suppression circuitry to protect against transient surges and high-frequency noise inherent in industrial environments. System integration is achieved through Mark VIe or Mark VIeS controller compatibility, utilizing the terminal board's ability to map 24 independent inputs to the associated I/O pack. Firmware flash compatibility across the Mark VIe ecosystem ensures that input timing and status reporting are synchronized with controller scan rates, facilitating efficient I/O density scaling during system expansion or migration.

Frequently Asked Questions

Q: Does the IS200STCIH6A support signal loop power generation?

A: No. The STCI board serves as an interface for external field contacts. Stimulation voltage must be provided by external sources; the board provides the termination and filtering required to condition these signals for the I/O pack.

Q: Can the STCI board be mounted in different orientations?

A: Yes. The board is designed for flexibility, supporting both standard DIN-rail mounting and direct flat-surface installation within the control cabinet, depending on specific panel layout requirements.

Field Installation Guidelines

  1. Mounting: Secure the board onto a standard DIN-rail or directly to the cabinet backplane using the mounting holes provided. Ensure the chassis ground point is firmly connected to the panel ground bus to ensure effective noise suppression.
  2. Wiring Termination: Connect field contact wiring to the designated screw terminals. For 125 V DC inputs, maintain appropriate wire insulation ratings and physical separation from low-voltage signal cabling to prevent cross-coupling.
  3. Shielding: Terminate cable shields at the cabinet ground point rather than the terminal board itself, unless specific site grounding diagrams dictate otherwise. Use ferrules on stranded conductors to ensure reliable mechanical connection within the terminal blocks.
  4. Verification: After installation, perform a continuity check on all field loops. Use a digital multimeter to confirm that the stimulation voltage is correctly present at the terminal entry point before signaling the I/O pack.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more