Product Overview

The Yokogawa AAR145-S00 functions as a high-density RTD (Resistance Temperature Detector) input interface for CENTUM VP and CS 3000 FIO systems. This module provides 16 isolated channels to capture precise temperature data from field-mounted RTD sensors. It utilizes a constant 1 mA measurement current to determine resistance changes, converting them into digital temperature values for the Distributed Control System (DCS). We supply this module as 100% brand new, original factory stock to ensure thermal measurement accuracy and long-term stability in your process control loops.

Part Number Breakdown: AAR145-S00

  • AAR145: RTD Input Module (16-channel, isolated).

  • -S: Standard type for general industrial temperature monitoring.

  • 0: Always 0 (Standard configuration).

  • 0: Basic type without specialized conformal coating.

Technical Specifications

  • Manufacturer: Yokogawa

  • Input Channels: 16 Isolated Channels

  • Measurement Current: 1 mA (RTD)

  • Data Update Period: 1 second

  • Allowable Input Voltage: ±5 V

  • Maximum Current Consumption: 350 mA (5 V DC)

  • Signal Source Resistance: 150 Ω or less (total resistance plus wiring)

  • Burn-out Detection: All channels (Detection time: 60 s)

  • External Connection: Dedicated KS8 / AKB335 cable

  • Weight: 0.3 kg

  • Condition: 100% Brand New Original

Engineering Advantages

The AAR145-S00 solves complex temperature acquisition challenges through high-performance circuitry and robust isolation:

  • Total Channel Isolation: This module provides full electrical isolation between all 16 channels and the system backplane. This prevents ground loops and ensures that a single sensor failure or electrical surge in the field does not affect the remaining inputs or damage the core DCS hardware.

  • Integrated Burn-out Detection: The AAR145 includes a configurable burn-out function that detects broken sensor wires or open circuits. By setting the system to drive the signal to a specific limit during a fault, it prevents the DCS from making control decisions based on erroneous "zero" readings.

  • High-Resolution Temperature Tracking: With a 1-second data update period and a stable 1 mA excitation current, the module tracks thermal fluctuations with high precision. This ensures the control system responds rapidly to process changes, maintaining tight temperature tolerances.

  • Dense Cabinet Integration: The slim 0.3 kg design allows for high-density I/O configurations. By utilizing dedicated KS8 or AKB335 cables, engineers simplify terminal board wiring and reduce the total cabinet space required for large-scale temperature monitoring projects.

FAQs

  • What type of cables should I use with the AAR145-S00?

    This module requires dedicated Yokogawa cables, specifically the KS8 or AKB335 series. These cables ensure proper shielding and signal integrity between the module and the terminal block.

  • Can I configure burn-out detection for individual channels?

    The AAR145 allows burn-out settings to be applied to all channels together. This ensures a consistent safety state across all 16 temperature points in the event of a sensor or wiring failure.

  • Does the module require external power for the RTDs?

    No. The AAR145 provides the 1 mA measurement current directly from its internal circuitry, drawing power from the FIO base module. You only need to connect the 3-wire or 4-wire RTD sensors to the field terminals.

  • Is this a genuine Yokogawa component?

    We guarantee that every AAR145-S00 we ship is 100% brand new and original. Each unit arrives in its original factory packaging and includes our comprehensive 1-year warranty.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more