Skip to content

What are you looking for?


You may also like

Allen-Bradley HART Analog Input 1756-IF8H ModuleAllen-Bradley HART Analog Input 1756-IF8H ModuleAllen-Bradley HART Analog Input 1756-IF8H Module
Allen-Bradley HART Analog Input 1756-IF8H Module
Allen-Bradley HART Analog Input 1756-IF8H Module
Allen-Bradley HART Analog Input 1756-IF8H Module

Allen-Bradley HART Analog Input 1756-IF8H Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IF8H

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The Allen-Bradley 1756-IF8H is an 8-channel HART-enabled analog input module for ControlLogix systems, offering precise measurement of voltage and current signals while supporting HART communication standards 5, 6, and 7. The module is designed for reliable signal acquisition with robust overvoltage protection, isolation, and high-resolution performance.

Technical Specifications

Module Details

  • Model: 1756-IF8H

  • Input Channels: 8 differential inputs with 1 HART modem per module

  • Input Voltage Ranges: 0…5V, 1…5V, 0…10V, ±10V

  • Input Current Ranges: 0…20 mA, 4…20 mA

  • Resolution: 16–21 bits across all ranges

  • Compatible HART Versions: HART 5, 6, 7

Performance

  • Analog Scan Time: 18–488 ms (filter dependent)

  • HART Scan Time: Typically 1 s per enabled channel; ~10 s for all 8 channels active

  • Open Circuit Detection: 5 s

  • Overvoltage Protection: 30V DC for voltage; 8V DC for current

  • Isolation Voltage: 50V continuous; basic insulation type; tested 1500V AC for 60 s, I/O to backplane

Accuracy & Calibration

  • Voltage Accuracy: Better than 0.05% of range (HART disabled)

  • Current Accuracy: Better than 0.15% of range (HART disabled)

  • Calibration Interval: 12 months typical

  • Temperature Rating: North America T4A / IEC T4

Environmental & Physical

  • Operating Temperature: 0°C to 60°C

  • Storage Temperature: -40°C to 85°C

  • Relative Humidity: 5–95% non-condensing

  • Enclosure: Open-style, no protective housing

Applications

The 1756-IF8H module is ideal for precise analog signal monitoring in process control, supporting HART communication for integration with smart field devices. Typical applications include level measurement, temperature control, and flow monitoring.

FAQ

Q: How many HART channels does the module support?
A: The module provides 1 HART modem for 8 differential analog inputs.

Q: What input types are supported?
A: Voltage (0…5V, 1…5V, 0…10V, ±10V) and current (0…20 mA, 4…20 mA).

Q: What is the update time for HART readings?
A: Typically 1 s per active HART channel; around 10 s if all 8 channels are enabled.

Q: Does it offer overvoltage protection?
A: Yes, 30V DC for voltage inputs and 8V DC for current inputs.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more