Description

The TU833 3BSE038726R1 is a passive baseplate for mounting S800 I/O modules on a DIN rail. The "Extended" version offers increased terminal capacity and improved wire management, supporting up to three wires per signal channel. It reduces the need for external marshalling panels by allowing direct connection of field power and signal return lines. The unit features mechanical keying to prevent incompatible module insertion, ensuring electrical safety and system reliability. Its durable design is built for continuous operation in process automation and power plant environments.

Specifications

  • Manufacturer: ABB

  • Model Number: TU833 (3BSE038726R1)

  • Product Type: Extended Module Termination Unit (MTU)

  • Terminal Arrangement: Three rows for signal, return, and ground

  • Maximum Rating: 50 V DC / 2 A per channel

  • Connection Method: Screw-clamp terminals

  • Conductor Range: 0.2 to 2.5 mm²

  • ModuleBus Interface: Dual support for redundancy

  • Operating Temperature: -25 to +70 °C

  • Weight: 0.50 kg

Features

  • Three-Wire Field Termination: Simplifies cabinet internal wiring by providing dedicated terminals for signal, power distribution, and return for each I/O point.

  • Redundant ModuleBus Support: Features dual internal bus connections to ensure continuous communication in high-availability system configurations.

  • Mechanical Safety Coding: Built-in physical keying prevents human error by ensuring only the correctly rated I/O module can be seated in the MTU.

  • Hot-Swap Capability: Allows for the live replacement of I/O modules without the need to disconnect field wiring or interrupt system power.

  • Integrated Shielding Terminals: Provides easy access for cable shield grounding, essential for maintaining signal integrity in high-EMI industrial zones.

  • High-Density Footprint: Designed to maximize cabinet space while providing clear terminal identification for rapid installation and troubleshooting.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more
Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Preventing Emergency Stop Spurious Trips in Industrial Control Systems

Emergency Stop pushbuttons use Normally Closed contacts for fail-safe safety, but mechanical wear can cause costly spurious trips. This technical guide examines E-Stop contact failure root causes, redundant hardware setups, PLC logic monitoring, and maintenance strategies to maximize plant availability.

Read more
Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Why 24V DC Is the Universal Standard for Industrial Automation Power Supplies

Industrial manufacturing requires continuous uptime to prevent equipment damage. Unlike AC power, 24V DC circuits seamlessly integrate with UPS units and battery banks. During main grid failures, a 24V DC backup system instantly maintains PLC memory, instrument loops, and critical safety valves without interruption.

Read more